Pioneer 403MKS
Pioneer Pulse 403MKS
5.1 PARTIAL RESET
The reset procedure involves restoration of the parameter values and settings, except the following
settings:
- Settings of the SETUP menu.
- saved JOBS.
ACTIVATION
A
S1
B
S2
EXIT
S3
S4
○ Set the welding power source ON/OFF switch to "O" to switch the unit off.
○ Set the welding power source ON/OFF switch to "I" to switch on the unit.
○ Simultaneously press the keys S1
A
out before the wording "PROGRAM UPDATE" appears in the following display: D3 ]
○
PARTIAL RESET SELECT TYPE OF RESET : The message will appear on display: D3
○ Exit without confirmation
- Set the welding power source ON/OFF switch to "O" to switch the unit off.
- Set the welding power source ON/OFF switch to "I" to switch on the unit.
○ Exit with confirmation
B
- Press S2
The display D3 will show the message: MEMORY CLEANING
- Wait for the memory clear procedure to terminate.
The unit restarts with the power-up procedure.
WELD THE WORLD
S T O P
L7
E1
D1
D3
and S10
to save the setting and quit the menu.
L4
L8
D2
S8
E3
S5
S6
S7
[
This operation must be carried
Cod. 006.0001.2230
02/09/2020 V.1.0
ENGLISH
E2
ACTIVATION
A
S10
S9
21