2.5 MIG/MAG INSTALLATION

Read the warnings highlighted by the following symbols in the "General prescriptions for use".
FRONT VIEW
REMOTE
CONTROL
1. Set the welding power source ON/OFF switch to "O" (unit switched off).
2. Connect the power source mains supply cable to the mains socket outlet.
3. Connect the gas hose from the welding gas cylinder to the relative socket.
4. Open the cylinder gas valve.
5. Connect the MIG/MAG torch plug to the EURO TORCH welding socket.
6. Connect the plug of the ground clamp to the welding socket on the basis of the polarity required.
7. Connect the plug of the polarity selector cable to the welding socket on the basis of the polarity
required.
8. Connect the earth clamp to the workpiece being processed.
9. Set the welding power source ON/OFF switch to "I" (unit powered).
10. Select the following welding mode on the user interface: MIG/MAG
11. Press the
key to feed the wire until it protrudes from the torch tip. The insertion speed is
2.0 m/min for 3 seconds, subsequently increasing to 15 m/min. When the button is released wire
feed is interrupted. This function produces a slower feed rate and hence greater precision when
inserting the wire when it enters the torch nozzle.
12. Select the torch trigger procedure on the user interface.
13. Open the gas solenoid valve by pressing and releasing the button
Use the flow control valve to adjust the flow of gas as required while the gas is flowing out.
15. Close the gas solenoid valve by pressing and releasing the button.