6.4 LOCKING PROCEDURE

The procedure inhibits unit adjustments, allowing the user to modify only certain settings depending on
the selected lock status. The procedure is used to prevent accidental alteration of the unit settings and
welding settings by the operator.
Enabling
If no locking status is selected (LOCK STATUS = OFF) and if you wish to set up a limitation on use of
the welding power source, display page 5/10 of the SETUP menu. During the normal operation, the
operator can enter the SET UP menu by pressing the key S5
be accessed with machine on).
S1
EXIT
D
S2
S3
C
S4
SETTING
○ Use the encoder E3
A
○ Press the S5
B
ENTER PASSWORD: 000 - The message wll appear on display: D3
-
Default password: 000
○ Enter a 4 digit numerical password.
○ Use buttons S3
C
The selected digit will flash .
○ Use encoder E3
28
WELD THE WORLD
E1
D3
to select the required lock status.
button to confirm.
and S4
to select the digit to be changed.
to set up the value.