9.3 3RD LEVEL

The menu contains the settings and values that are changed infrequently and are to be set up the first
time the unit is powered up.
The changed parameters remain saved until the next modification or reset of the unit.
§ "6 SET-UP (INITIAL SET-UP OF THE WELDING POWER SOURCE)".
Menu level
Selected parameter.

10 WELDING SETTINGS

10.1 WELDING CURVES SELECTION

○ Select parameter MAT by pressing buttons S3
- Using the encoder E3
○ Select parameter Ø by pressing buttons S3
- Using the encoder E3
○ Select parameter GAS by pressing buttons S3
- Using the encoder E3

10.1.1 Special curves: POWER FOCUS and POWER ROOT

No specific procedures are required to activate these curves. The special curves appear in the list to-
gether with the standard curves.
WELD THE WORLD
SET UP
COOLING TYPE
SHORT/SPRAY
MAT
SG2/SG3
GAS: 80% Ar / 20% CO2
JOB : FE55 MARIO
and S4
, edit the value of the selected parameter.
and S4
, edit the value of the selected parameter.
and S4
, edit the value of the selected parameter.
x / y
x = number of the currently dis-
played menu page.
y = total number of menu pages.
ON
Set value.
SYN
Ø:1.2
R4
K1
.
.
.
Cod. 006.0001.2230
02/09/2020 V.1.0
ENGLISH
45