(D). The electrode (A) must be replaced when a crater in the centre of about 1 mm deep is present. The new electrode must be screwed into The Discovery 35P / Discovery 45P is a compact and heavy duty place and tightened up without screwing it right down. The nozzle (C) generator for plasma cutting.
Cod.006.0001.0320 Discovery 35P 09/01/2014 v2.5 Discovery 45P ENGLISH REAR PANEL PLASMA CUTTING The generator must only be used for operations of cutting electrically conductive materials (metals and their alloys) except for coated metals or those containing lead Pb, cadmium Cd, zinc Zn, chrome Cr, mercury Hg, beryllium Be and graphite if specific fume extraction systems are not available.
Cod.006.0001.0320 Discovery 35P 09/01/2014 v2.5 Discovery 45P ENGLISH COMMISSIONING USER INTERFACE CODE SYMBOL DESCRIPTION Overheating alarm Indicates tripping of the welding power source thermal protection. Leave the unit running so that the overheated components cool as rapidly as possible. When the unit has cooled, the welding power source will reset automatically.
Cod.006.0001.0320 Discovery 35P 09/01/2014 v2.5 Discovery 45P ENGLISH TECHNICAL DATA DISCOVERY 35P Waste electrical and electronic equipment (WEEE) Electromagnetic compatibility (EMC) Directives applied Low voltage (LVD) Restriction of the use of certain hazardous substances (RoHS) Construction standards EN 60974-1; EN 60974-10 Class A...
Cod.006.0001.0320 Discovery 35P 09/01/2014 v2.5 Discovery 45P ENGLISH DISCOVERY 45P 2002/96/EC-Waste electrical and electronic equipment (WEEE) 2004/108/EC-Electromagnetic compatibility (EMC) Directives applied 2006/95/EC-Low voltage (LVD) 2011/65/EU-Restriction of the use of certain hazardous substances (RoHS) Construction standards EN 60974-1; EN 60974-10 Class A...