Double Pulsed Synergic Mig/Mag Parameters Setting (1St Level): Synergic Curve Setting; Double Pulsed Synergic Mig/Mag Parameters Setting (2Nd Level) - Weco Pioneer 403MKS Instruction Manual

Table of Contents

Advertisement

Cod. 006.0001.2230
02/09/2020 V.1.0
ENGLISH
S6
This button serves to select the following welding mode:
MODE
MODE
DOUBLE PULSED SYNERGIC MIG/MAG
S7
Use this button to select one of the following torch trigger procedures:
2 STROKE
2 STROKE SPOT: The procedure is active when the "SPOT TIME" parameter is set to a value other
than "OFF".
A
4 STROKE
4 STROKE B-LEVEL: The procedure is active when the "B-LEVEL" parameter is set to a value other
than "OFF"
3 LEVEL 2 STROKE
3 LEVEL 2 STROKE SPOT: The procedure is active when the "SPOT TIME" parameter is set to a value
other than "OFF". If the "SPOT TIME" parameter is active in the 3 LEVELS procedure, its value denotes
the time for which the main welding current is supplied.
3 LEVEL 4 STROKE
3 LEVEL 4 STROKE B-LEVEL: The procedure is active when the "B-LEVEL" parameter is set to a value
other than "OFF"
Tab. 11 - Main settings and displays in DOUBLE PULSED SYNERGIC MIG/MAG mode
Shows the main synergy param-
eter (wire feed rate, Amperes,
Data setting
recommended thickness), which
can be adjusted with the following
Shows the average current meas-
Welding
Shows the average current
HOLD function
measured during the last welding
(At welding end)

10.5.1 Double pulsed synergic MIG/MAG parameters setting (1st level): synergic curve setting.

B
○ Scroll down the list of parameters to be edited by pressing buttons S3
○ Using the encoder E3
C
The value is saved automatically.

10.5.2 Double pulsed synergic MIG/MAG parameters setting (2nd level).

D
○ Press the button S5
B
○ Scroll down the list of parameters to be edited by pressing buttons S3
58
WELD THE WORLD
DISPLAY D1
encoder: (E1).
ured during welding.
procedure performed.
, edit the value of the selected parameter
to enter the 2nd level menu.
DISPLAY D2
Shows the set welding voltage,
which can be adjusted with the
following encoder: (E2).
Shows the average voltage
measured during welding.
Shows the average voltage
measured during the last weld-
ing procedure performed.
Pioneer 403MKS
Pioneer Pulse 403MKS
DISPLAY D3
Shows the arc correction
executed by the operator with
encoder (E2). Displays D2
and D3 change simultaneous-
ly, but while display D2 shows
the absolute value, display
D3 shows the correction with
respect to the standard and
optimal value proposed by the
manufacturer.
Shows the arc correction
executed by the operator.
Shows the arc correction
executed by the operator.
and S4
and S4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pioneer pulse 403mks