Total Reset - Weco Pioneer 403MKS Instruction Manual

Table of Contents

Advertisement

Cod. 006.0001.2230
02/09/2020 V.1.0
ENGLISH

5.2 TOTAL RESET

The reset procedure involves complete restoration of the default values, parameters and memory set-
tings set in the factory.
All memory locations will be reset and hence all your personal welding settings will be lost!
ACTIVATION
A
S1
C
S2
EXIT
S3
S4
○ Set the welding power source ON/OFF switch to "O" to switch the unit off.
○ Set the welding power source ON/OFF switch to "I" to switch on the unit.
○ Simultaneously press the keys S1
A
out before the wording "PROGRAM UPDATE" appears in the following display: D3 ]
PARTIAL RESET SELECT TYPE OF RESET : The message will appear on display: D3
B
○ Use the encoder E3
○ Exit without confirmation
- Set the welding power source ON/OFF switch to "O" to switch the unit off.
- Set the welding power source ON/OFF switch to "I" to switch on the unit.
○ Exit with confirmation
C
- Press S2
The display D3 will show the message: MEMORY CLEANING
- Wait for the memory clear procedure to terminate.
The unit restarts with the power-up procedure.
22
WELD THE WORLD
S T O P
L7
E1
D1
D3
IMPOSTAZIONE
and S10
, to select the following "TOTAL RESET ".
to save the setting and quit the menu.
L4
L8
D2
S8
E3
S5
S6
S7
B
[
This operation must be carried
Pioneer 403MKS
Pioneer Pulse 403MKS
E2
ACTIVATION
S10
S9
A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pioneer pulse 403mks

Table of Contents