■Error display

Error name
Error display
Instantaneous flow
error
Pressure error
Temperature error
Over current error
System error
Description
Flow rate exceeding the upper limit
of the settable flow range is applied.
Pressure exceeding the upper limit
of the set pressure range is applied.
Pressure below the lower limit of the
set pressure range is applied.
Temperature exceeding the upper
limit of the set temperature range is
applied.
Temperature below the lower limit of
the set temperature range is applied.
The switch output load current is
80 mA or more.
to
An internal data error has occurred.
Reset applied flow rate to a level within
the settable flow range.
Reset applied pressure to a level within
the set pressure range.
Reset applied temperature to a level
within the settable temperature range.
Turn the power off and remove the
cause of the over current. Then supply
the power again.
Turn the power off and on again.
If the failure cannot be solved, contact
SMC.