Quick Links

3-Colour Display
Digital Flow Switch
Applicable fluid
3
-colour/
Instantaneous
flow rate
(Main screen)
Set value
(Sub screen)
Expanded flow range
A wide range of flow measurement is possible
with 1 product.
2
Flow ratio
∗2 Rated flow ratio is 10 : 1 for the existing PF2A series model.
Rated flow range [l/min]
1 2 5 10 20 25 50 100 150 200
5
500 L type
10
1000 L type
20
Smallest settable increment
5 l/min for the for the existing
5 l/min for t
the for the existing
PF2A series model
PF2A serie
es model
PFMC7 (-L)
Dry air, N
2
2
-screen display
100:1
300
500
600
1000
500
1000
2000
2000 L type
1
l/
l/
l/min
/min
Series
1
∗1 2-row display of main screen and sub screen
New
New
The flow rate value and the device status can be
figured out easily via the process data.
Diagnosis items
Over current error
Above the rated/
2000
accumulated flow range
Below the rated/
accumulated flow range
Internal product malfunction
RoHS
IP65
∗ For the PFMC7 -L
Accumulated value
Peak/Bottom value
Line name
Compatible
2
p.
3-Screen Display
Digital Flow Monitor
Allows for the monitoring
of remote lines
PFG300
Series
CAT.EUS100-115C-UK

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PFMC7-L Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SMC Networks PFMC7-L Series

  • Page 1 3-Colour Display RoHS Digital Flow Switch IP65 Applicable fluid Dry air, N ∗ For the PFMC7 -L ∗ -colour/ -screen display Accumulated value ∗1 2-row display of main screen and sub screen Peak/Bottom value Instantaneous flow rate (Main screen) Set value Line name (Sub screen) Expanded flow range...
  • Page 2 Digital Flow Switch 3-Colour Display PFMC7(-L) Series Clockwise ° Counterclockwise ° Rotary display Functions 24, 25 , 25 Output operation Forced output function Peak/Bottom value display Display can be rotated in increments of Display colour Accumulated value hold Key-lock function 45°...
  • Page 3: Display Function

    Digital Flow Switch PFMC7(-L) 3-Colour Display Series IO-Link Compatible PFMC7 - -L - Supports the IO-Link communication protocol Configuration File (IODD File ∗ IO-Link is an open communication interface technology between the sensor/actuator and the I/O terminal that is an international ·...
  • Page 4 Digital Flow Monitor 3-Screen Display PFG300 Series Allows for the monitoring of remote lines PF3A7 H Centralized flow control PFG300 For main line PFG300 PFG300 PFMB PFG300 PFG300 PFMC The flow rate of a flow switch installed in a distant location can be confirmed! Visualization of settings The sub screen (label) shows the item...
  • Page 5: Convenient Functions

    Digital Flow Monitor PFG300 3-Screen Display Series NPN/PNP switch function Input range selection (for Pressure/Flow rate) The number of stock items can be reduced. The displayed value to the sensor input can be set as required. (Voltage input: 1 to 5 V/Current input: 4 to 20 mA) Pressure switch/Flow switch can be displayed.
  • Page 6 Flow Switch Flow Rate Variations Rated flow range [l/min] Applicable Detection Series fluid method −3 −2 −1 −0.5 PFMV Dry air Thermal type (MEMS) Series Rated flow range [l/min] Applicable Detection Smallest settable Compatibility with the fluid method increment 5 10 20 25 50 100 150 200 300 500 600 1000 2000...
  • Page 7 Flow Switch Variations / Basic Performance Table PFMV PF2M7(-L) PFMB PFMC7(-L) PF2A PF3A7„H(-L) PFG300 PFMV3 PFG300 PFG300 IP65 IP65 IP40 IP40 IP40 IP65 [Monitor unit: IP40] [Monitor unit: IP40] Dry air, Dry air, N Dry air, N Dry air, N Air, N Air, N , Ar, CO...
  • Page 9 C O N T E N T S Digital Flow Switch PFMC7 3-Colour Display Series IO-Link Compatible 3-Colour Display Digital Flow Switch PFMC7-L Series Digital Flow Monitor PFG300 3-Screen Display Series Digital Flow Switch PFMC7 3-Colour Display Series How to Order p.
  • Page 10: How To Order

    3-Colour Display Digital Flow Switch ® PFMC7 Series RoHS How to Order PFMC Rated flow range Calibration certificate — None 5 to 500 ∗ 10 to 1000 ∗8 Made to order 20 to 2000 The certifi cate is in both English and Japanese.
  • Page 11: Specifications

    PFMC7 Series 3-Colour Display Digital Flow Switch For fl ow switch precautions and specifi c product precautions, refer to the “Operation Manual” on the SMC website. Specifi cations Model PFMC7501 PFMC7102 PFMC7202 Dry air, N Applicable fl uid Fluid (Air quality grade is JIS B 8392-1 1.1.2 to 1.6.2, ISO 8573-1 1.1.2 to 1.6.2.) Fluid temperature range 0 to 50 °C Detection method...
  • Page 12 Digital Flow Switch 3-Colour Display PFMC7-L Series RoHS How to Order PFMC Type Integrated display Rated flow range Calibration certificate — 5 to 500 None ∗ 10 to 1000 20 to 2000 ∗9 Made to order The certifi cate is in both English and Japanese. Thread type Option 2 —...
  • Page 13 PFMC7-L Series 3-Colour Display Digital Flow Switch For fl ow switch precautions and specifi c product precautions, refer to the “Operation Manual” on the SMC website. Specifi cations PFMC7-L Model When used as a switch 12 to 24 VDC ±10 % Power output device Electrical...
  • Page 14: Flow Range

    PFMC7(-L) Series Flow Range Flow range Model –100 l/min 0 l/min 200 l/min 500 l/min 1000 l/min 2000 l/min 5 l/min 500 l/min PFMC7501(-L) 5 l/min 525 l/min –25 l/min 525 l/min 10 l/min 1000 l/min PFMC7102(-L) 10 l/min 1050 l/min –50 l/min 1050 l/min 20 l/min...
  • Page 15 PFMC7(-L) Series Digital Flow Switch 3-Colour Display Internal Circuits and Wiring Examples NPN (2 outputs) type PNP (2 outputs) type PFMC7 -A - PFMC7 -B - Brown Brown DC (+) DC (+) Black Black OUT1 OUT1 12 to 12 to 24 VDC 24 VDC −...
  • Page 16 PFMC7(-L) Series Internal Circuits and Wiring Examples PFMC7 - -L - PNP output type NPN output type Brown Brown DC (+) DC (+) Black Black OUT1 OUT1 12 to 24 VDC 12 to 24 VDC White N.C. White N.C. Blue Blue DC (−) DC (−)
  • Page 17: Component Parts

    PFMC7(-L) Series Digital Flow Switch 3-Colour Display Construction: Parts in Contact with Fluid Component Parts Description Material Note Sensor body Gasket HNBR Flow rectifi er Stainless steel 304 Sensor chip Silicon Printed circuit board GE4F Gasket HNBR Body Aluminum alloy Anodized Mesh Stainless steel 304...
  • Page 18: Cable Specifications

    PFMC7(-L) Series Dimensions PFMC7501/7102/7202(-L) 2 x Port size (35.5) 2 x M3 x 0.5 depth 5 Symbol Port size Model PFMC7501/7102(-L) Rc1/2, NPT1/2 60.6 41.2 13.6 PFMC7202(-L) Rc3/4, NPT3/4, G3/4 66.1 46.7 17.5 16.8 PFMC7501/7102(-L) G1/2 60.6 41.2 13.6 Bracket dimensions Symbol Model PFMC7501/7102(-L)
  • Page 19: Screen Display

    3-Screen Display Digital Flow Monitor PFG300 Series RoHS How to Order Type Remote type monitor unit Input specification Option 4 Symbol Description Applicable fl ow switch model Operation manual Calibration certifi cate Voltage input PFMC7 -C/E/L3 series — — Current input PFMC7 -D/F/L4 series —...
  • Page 20 PFG300 Series For fl ow switch precautions and specifi c product precautions, refer to the “Operation Manual” on the SMC website. Specifi cations Model PFG300 series Model PFMC7501 PFMC7102 PFMC7202 Applicable SMC Rated fl ow range ∗ fl ow switch 5 to 500 10 to 1000 20 to 2000...
  • Page 21 PFG300 Series Digital Flow Monitor 3-Screen Display Internal Circuits and Wiring Examples NPN (2 outputs) + Copy function PNP (2 outputs) + Copy function qDC (+) qDC (+) Brown Brown DC (+) DC (+) Gray Gray Copy terminal Copy terminal rAnalog rAnalog input...
  • Page 22 PFG300 Series Dimensions Sensor connector 4 x Ø 2.6 (7.7) Depth 7 or less Power supply/Output connector Bracket A (Part no.: ZS-46-A1) 34.6 ∗ Bracket configuration allows for mounting in four orientations. Bracket B (Part no.: ZS-46-A2) ∗ Bracket configuration allows for mounting in four orientations.
  • Page 23 PFG300 Series Digital Flow Monitor 3-Screen Display Dimensions Panel mount adapter (Part no.: ZS-46-B) 50.8 34.5 20.2 47.8 Panel thickness 0.5 to 7 Panel mount adapter + Front protection cover (Part no.: ZS-46-D) 50.8 20.2 47.8 34.5 33.5 42.4 Panel thickness 0.5 to 7 Power supply/output connection lead wire Sensor connector (Part no.: ZS-46-5L)
  • Page 24 PFG300 Series Dimensions Panel fi tting dimensions Individual mounting −0.4 Multiple (2 pcs. or more) secure mounting Panel mount example <Horizontal> <Horizontal> 31 x n pcs. + 3.5 x (n pcs. − 1) Panel mount example <Vertical> <Vertical> 24 or more −0.4...
  • Page 25: Function Details

    The life time of the memory device is 1 million access times. Take this into consideration before using this function. Display The display of the PFMC7 series and that of the PFMC7-L series differs slightly. Main screen (2-colour display) Main screen (2-colour display)
  • Page 26 PFMC7(-L) Series Analogue output free range function This function allows a fl ow that generates an output of 5 V (or 10 V when 0 to 10 V is selected) or 20 mA to be changed. The value can be changed between 10 % of the maximum value of the rated fl...
  • Page 27 PFG300 Series Function Details Output operation Forced output function The output operation can be selected from the following: The output is turned on/off in a fi xed state when starting the system Output (hysteresis mode and window comparator mode) correspond- or during maintenance.
  • Page 28 PFG300 Series Selection of display on sub screen The display on the sub screen in measuring mode can be set. Set value display Accumulated value display Peak value display Displays the set value Displays the accumulated value Displays the peak value screen Bottom value display Line name display...
  • Page 29 PFG300 Series Function Details Copy function The settings of the master monitor can be copied to the slave monitors, reducing setting labor and minimizing the risk of setting mistakes. The set value can be copied to up to 10 fl ow monitors simultaneously. (Maximum transmission distance: 4 m) 1 unit 2 units...
  • Page 30: Safety Instructions

    These safety instructions are intended to prevent hazardous situations and/or equipment Safety Instructions damage. These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.” They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC) , and other safety regulations.
  • Page 31 Revision History - The digital fl ow monitor PFG300 series has been Edition B added. - Number of pages has been increased from 16 to 28. - IO-Link compatible products (PFMC7-L) have been Edition C added. - Number of pages has been increased from 28 to 32. SMC Corporation (Europe) +43 (0)2262622800 www.smc.at offi...

This manual is also suitable for:

Pfmv seriesPf2m7-l seriesPf2a seriesPf3a7h-l series

Table of Contents