■Piping

•Fit the raised part of the spacer to the recessed part (groove for the raised part) of the product.
•Tighten the retainer A with two hexagon socket head cap screws temporarily.
•Tighten the two hexagon socket head cap screws with a hexagonal wrench evenly.
Refer to the control items shown below for the tightening torque for the screws.
Control items
Applicable model
PF3A801H
PF3A802H
•The following options are required for coupling with modular F, R, and L combinations. They are separately
prepared by the user.
Digital flow switch
PF3A801H
PF3A802H
: For more information about the options, refer to our website (URL https://www.smcworld.com).
Hexagonal wrench socket size
Nominal value
3
Air combination
AC30#-D
AC40#-D
-20-
Tightening torque
1.2±0.05 Nm
Spacer
Spacer with bracket
Y300-D
Y300T-D
Y400-D
Y400T-D
Pipe adapter
E300-#03-D
E400-#04-D
No.PF※※-OMY0005