Maintenance; Forgotten The Security Code - SMC Networks PF3A801H-L Operation Manual

Digital flow switch modular type
Hide thumbs Also See for PF3A801H-L:
Table of Contents

Advertisement

Maintenance

How to reset the product after a power loss or when the power has been unexpectedly removed
The settings for the product are retained in memory prior to the power loss or de-energizing of the product.
The output condition is also recoverable to that prior to the power loss or de-energizing. However, this may
change depending on the operating environment. Therefore, check the safety of the whole installation before
operating the product.
If the installation is using accurate control, wait until the product has warmed up (approximately 10 to 15
minutes) before operation.

Forgotten the Security Code

Use the procedure below when the security code has been forgotten.
<Operation>
Press the SET button for 5 seconds or longer in measurement mode. When [oPE] is displayed on the main
display, release the button.
The current setting [LoC] or [UnLoC] will be displayed on the sub display.
Press the UP or DOWN buttons simultaneously for 5 seconds or longer.
Press the SET and DOWN buttons simultaneously for 5 seconds or longer.
: Display is not changed.
(If an other operation is performed or no operation is performed for 30 seconds, the display will return to
measurement mode.)
Press the UP and SET buttons simultaneously for 5 seconds or longer.
[000] is displayed and the security code change mode is available.
(If an operation is not performed for 30 seconds, the display will return to measurement mode.)
For the input method, refer to [F81] Security code (checking of the setting of security code) (page 55).
When input is completed, the selected security code flashes.
After checking the security code is as required, press the SET button for 1 second or longer.
Return to measurement mode.
At this time, if the UP or DOWN button are pressed, any security code changes are lost, and the change of
security code must be repeated.