●Product individual parameters
Index
Sub
Access
1
index
dec
hex
Flow Unit
1000 0x03E8
0
R/W
(Selection of display unit)
CoL
1010 0x03F2
0
R/W
(Selection of display colour)
N or P
1020 0x03FC
0
R/W
(Switch NPN/PNP)
1070 0x042E
0
R/W
Reference condition
Temperature Unit
1080 0x0438
0
R/W
(Selection of temperature
display unit)
Pressure Unit
1090 0x0442
0
R/W
(Selection of pressure
display unit)
1200 0x04B0
0
R/W
1
R/W
1210 0x04BA
2
R/W
1
R/W
2
R/W
3
R/W
1220 0x04C4
4
R/W
5
R/W
6
R/W
7
R/W
Data
Initial
Parameter
type
value
2
U8
0
U8
2
U8
1
U8
0
U8
0
U8
0
OUT1
U8
0
(Select the target for
setting)
ModE1
U8
0
(Selection of output
mode)
1ot
(Selection of output
U8
0
type)
P_1 (n_1)
(Selection of output
S16
2000
set value)
H_1
U16
200
(Setting of OUT1
hysteresis)
P1L (n1L)
S16
1200
(Lower limit of window
comparator)
P1H (n1H)
(Upper limit of window
S16
2400
comparator)
WH1
U16
400
(Window comparator
hysteresis)
dtH1
U16
0
(Delay time ON)
dtL1
U16
0
(Delay time OFF)
-82-
Data
4
storage
Set value
3
0: L/min (L)
Y
3
1: cfm (ft
)
0: rEd (Constantly red)
1: Grn (Constantly green)
2: 1SoG
(OUT1 turns green at ON)
3: 1Sor
Y
(OUT1 turns red at ON)
4: 2SoG
(OUT2 turns green at ON)
5: 2Sor
(OUT2 turns red at ON)
0: nPn
Y
1: PnP
0: std
(Standard condition)
Y
1: nor
(Normal condition)
0: C
Y
1: F
0: MPa
1: kPa
2
Y
2: kgf/cm
3: bar
4: psi
0: FLoW (Flow rate)
1: Temp (Temperature)
2: PrES (Pressure)
3: AC (Accumulated)
Y
4: PLS
(Accumulated pulse)
5: Err (Error output)
6: oFF (Output OFF)
0: HYS (Hysteresis)
Y
1: Wind
(Window comparator)
0: 1_P (Normal output)
Y
1: 1_n (Reverse output)
Setting range
Y
0x0028 to 0x1068
(40 to 4200)
Setting range
Y
0x0000 to 0x1040
(0 to 4160)
Setting range
Y
0x0028 to 0x1068
(40 to 4200)
Setting range
Y
0x0028 to 0x1068
(40 to 4200)
Setting range
Y
0x0000 to 0x0820
(0 to 2080)
Y
Setting range
0x0000 to 0x1770
(0 to 6000)
Y
Remarks
When the unit selection function is not
included, a read/write to an
un-selectable item is rejected.
Setting of display colour
Setting the switch output
When the unit selection function is not
included, a read/write to an
un-selectable item is rejected.
When the unit selection function is not
included, a read/write to an
un-selectable item is rejected.
Setting of OUT1 output normal and
reserved output
Setting of OUT1 output set value
(Hysteresis)
Setting of OUT1 hysteresis
(Hysteresis)
Setting of OUT1 output set value
(Lower limit of window comparator)
Setting of OUT1 output set value
(Upper limit of window comparator)
Setting of OUT1 hysteresis
(Window comparator)
Setting of OUT1 delay time ON
10 ms increments
Setting of OUT1 delay time OFF
10 ms increments
No.PF※※-OMY0005