b. Accumulated flow is selected
Reversed output setting
Press the UP or DOWN button to select reversed output.
Press the SET button to set.
Select accumulated increment (addition) or decrement (subtraction)
Press the UP or DOWN button to select the accumulated increment
(addition)/decrement (subtraction).
: For Accumulated decrement, OUT1 or OUT2 is displayed.
The switch output can be set individually.
Press the SET button to set.
Setting of set value
Press the UP or DOWN button to change the value.
Press the SET button to move to the digit to the right.
Press the SET button for 1 second or longer to flash all digits.
Press the SET button while all the digits are flashing to move to the next step.
Press the SET button to set.
Move on to the accumulated increment (addition)/
decrement (subtraction).
Move on to setting of set value.
The accumulated output setting range is displayed by the set value of
the 9 digits and the units (x10
Return to function selection mode.
[F 1] Setting of OUT1 completed
-41-
3
L).
No.PF※※-OMY0005