●Set pressure range
Zero cut-off set value
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
Zero cut-off range
0%F.S.
0 to 1%F.S.
0 to 2%F.S.
0 to 3%F.S.
0 to 4%F.S.
0 to 5%F.S.
0 to 6%F.S.
0 to 7%F.S.
0 to 8%F.S.
0 to 9%F.S.
0 to 10%F.S.
-50-
Displayable pressure range
-0.050 to 1.050 MPa
-0.050 to -0.010 MPa
0.010 to 1.050 MPa
(Displays 0 when the value is -0.009 to 0.009 MPa)
-0.050 to -0.020 MPa
0.020 to 1.050 MPa
(Displays 0 when the value is -0.019 to 0.019 MPa)
-0.050 to -0.030 MPa
0.030 to 1.050 MPa
(Displays 0 when the value is -0.029 to 0.029 MPa)
-0.050 to -0.040 MPa
0.040 to 1.050 MPa
(Displays 0 when the value is -0.039 to 0.039 MPa)
-0.050 MPa
0.050 to 1.050 MPa
(Displays 0 when the value is -0.049 to 0.049 MPa)
0.060 to 1.050 MPa
(Displays 0 when the value is below 0.060 MPa)
0.070 to 1.050 MPa
(Displays 0 when the value is below 0.070 MPa)
0.080 to 1.050 MPa
(Displays 0 when the value is below 0.080 MPa)
0.090 to 1.050 MPa
(Displays 0 when the value is below 0.090 MPa)
0.100 to 1.050 MPa
(Displays 0 when the value is below 0.100 MPa)
No.PF※※-OMY0005