SMC Networks PF3A801H-L Operation Manual page 93

Digital flow switch modular type
Hide thumbs Also See for PF3A801H-L:
Table of Contents

Advertisement

Problem Possible
Error indication
Incorrect power
supply
The display turns
off.
Incorrect wiring
Part of the display
is missing.
Display off mode
Product failure
Display flashes
Incorrect wiring
Foreign matter
entered
The display
accuracy does not
Air leakage
meet the
specifications.
Warming up
inadequate
Product failure
Model Selection
(model selected
Display
does not have unit
measurement unit
conversion
cannot be
function)
changed.
Product failure
Key-lock mode is
Buttons do not
activated.
work
Product failure
Air leakage
There is noise.
Product failure
Investigation method
causes
Check if the power supply voltage is
21.6 to 30 V.
Check the power supply wiring
Check if the brown and blue wires are
connected to DC(+) and DC(-)
respectively, and if the wiring is secure
Check if display off mode is selected.
(1) Check the power supply wiring.
(2) Check if there is bending stress
applied to any part of the lead wire.
Confirmed foreign matter entry or
sticking to the piping port.
Check if air is leaking from the piping.
Check if the product satisfies the
specified accuracy 10 minutes after
supplying power.
Check if the product number printed on
the product indicates Unit selection
function type.
Check if the key-lock function is turned
on.
Check if air is leaking from the piping.
-92-
Countermeasure
Power supply voltage is 21.6 to
30 V.
Check and correct the wiring.
Select the power saving mode
again.
Replace the product
(1) Check and correct the wiring.
(2) Correct the wiring (bend
radius and stress).
Use a filter to prevent foreign
matter from entering or sticking.
Discharge the condensate of the
filter periodically.
Rework the piping.
If the tightening torque is
exceeded, the mounting screws,
brackets and the flow switch may
be damaged.
After energizing, the display and
output can drift. Allow the product
to warm up for 10 to 15 minutes.
Replace the product
Unit selection function is not
available for Fixed to SI units
type.
: The unit conversion function is
not for use in Japan due to a
new measurement law.
: Unit fixed to SI:L/min
Replace the product
Check the key-lock function.
Replace the product
Rework the piping.
If the tightening torque is
exceeded, the mounting screws
and the switch may be damaged.
Replace the product
No.PF※※-OMY0005

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pf3a802h-l

Table of Contents