●Product individual parameters (continued)
Index
Access
Sub
1
index
dec
hex
1290 0x050A
0
R/W
1300 0x0514
0
R/W
1310 0x051E
0
R/W
1320 0x0528
0
R/W
1330 0x0532
0
R/W
1340 0x053C
0
R/W
1400 0x0578
0
R/W
1
R/W
1410 0x0582
2
R/W
1
R/W
2
R/W
3
R/W
1420 0x058C
4
R/W
5
R/W
6
R/W
7
R/W
Data
Initial
Parameter
type
value
2
AC_1ot
(Selection of output
U8
0
type)
P1(n1)_L
U32
0
(Selection of output
set value)
P1(n1)_ft3
U32
0
(Selection of output
set value)
U8
0
PLS1_L
3
PLS1_Ft
U8
0
1ot
U8
0
(Selection of output
type)
OUT2
(Select the target for
U8
0
setting)
ModE2
U8
0
(Selection of output
mode)
2ot
U8
0
(Selection of output
type)
P_2 (n_2)
(Selection of output
S16
2000
set value)
H_2
U16
200
(Setting of OUT1
hysteresis)
P2L (n2L)
S16
1200
(Lower limit of window
comparator)
P2H (n2H)
S16
2400
(Upper limit of window
comparator)
WH2
(Window comparator
U16
400
hysteresis)
dtH2
U16
0
(Delay time ON)
dtL2
U16
0
(Delay time OFF)
-84-
Data
4
storage
Set value
3
0: 1_P (Normal output)
Y
1: 1_n (Reverse output)
Y
0 to 999,999,999
Y
0 to 999,999,999
0: 10 (L/pulse)
Y
1: 100 (L/pulse)
1000 L range
0: 0.1 (L/pulse)
1: 1(L/pulse)
Y
2000 L range
3
0: 1 (Ft
/pulse)
3
1: 10 (Ft
/pulse)
0: 1_P (Normal output)
Y
1: 1_n (Reverse output)
0: FLoW (Flow rate)
1: Temp (Temperature)
2: PrES (Pressure)
3: AC (Accumulated)
Y
4: PLS
(Accumulated pulse)
5: Err (Error output)
6: oFF (Output OFF)
0: HYS (Hysteresis)
Y
1: Wind
(Window comparator)
0: 1_P (Normal output)
Y
1: 1_n (Reverse output)
Setting range
Y
0x0028 to 0x1068
(40 to 4200)
Setting range
Y
0x0000 to 0x1040
(0 to 4160)
Setting range
Y
0x0028 to 0x1068
(40 to 4200)
Setting range
Y
0x0028 to 0x1068
(40 to 4200)
Setting range
Y
0x0000 to 0x0820
(0 to 2080)
Y
Setting range
0x0000 to 0x1770
(0 to 6000)
Y
Remarks
Common for all ranges, units, and
criterion
Common for all ranges, units, and
criterion
OUT1 accumulated pulse converted
value setting
Setting of OUT1 output normal and
reserved output.
Setting of OUT2 output normal and
reserved output
Setting of OUT2 output set value
(Hysteresis)
Setting of OUT2 hysteresis
(Hysteresis)
Setting of OUT2 output set value
(Lower limit of window comparator)
Setting of OUT2 output set value
(Upper limit of window comparator)
Setting of OUT2 hysteresis
(Window comparator)
Setting of OUT2 delay time ON
10 ms increments
Setting of OUT2 delay time OFF
10 ms increments