Default Setting - SMC Networks PF3A801H-L Operation Manual

Digital flow switch modular type
Hide thumbs Also See for PF3A801H-L:
Table of Contents

Advertisement

■Default setting

Main display
Main display
(Right)
(Left)
FLoW
FLoW
tEMP
PrES
[F 0]
-
oUt1
FLoW
FLoW
FLoW
[F 1]
FLoW
FLoW
FLoW
oUt2
FLoW
FLoW
FLoW
[F 2]
FLoW
FLoW
FLoW
FLoW
[F 3]
PrES
[F 6]
PrES
[F13]
-
FLoW
[F14]
PrES
PrES
[F16]
tEMP
AC
[F30]
AC
[F80]
[F81]
[F90]
-
[F96]
[F98]
[F99]
1: Setting is only possible for models with the units selection function.
Function
Sub display
(Left)
[rEF ] Select display units
[Unit] Units selection function
[NorP] Select NPN/PNP
[oUt1] Select the output of OUT1
[oUt2] Select the output of OUT2
[CoL ] Select display colour
[SW1 ] Select the target for setting
[ModE] Select switch mode
[1ot ] Select switch operation
[P_1 ] Input the set value
[H_1 ] Input of hysteresis
[dtH1] ON delay time setting
[dtL1] OFF delay time setting
[SW2 ] Select the target for setting
[ModE] Select switch mode
[2ot ] Select switch operation
[P_2 ] Input the set value
[H_2 ] Input of hysteresis
[dtH2] ON delay time setting
[dtL2] OFF delay time setting
[FiL ] Select digital filter
[FSC ] Display value fine adjustment
[rEv ] Select reverse display
[CUt ] Select Zero cut-off setting
[MES ] Measurement display setting
[SAvE] Accumulated value hold
[diSP] Display OFF mode
[Pin ]Security code
[ALL ] Setting of all functions
[CYCL] Check of cycle time
[tESt] Setting of output check
[ini ] Reset to the default settings
Default Settings
Sub display
(Right)
[ Std] Standard condition
[
L] L/min
1
o
[
C]
C
[ MPA] MPa
[ PNP] PNP output
[FLoW] Flow rate
[FLoW] Flow rate
[1SoG] Green when ON
Red when OFF (OUT1)
[FLoW] Flow rate
[ HYS] Hysteresis mode
[ 1_P] Normal output
[ 500] 500 L/min (PF3A801H)
[1000] 1000 L/min (PF3A802H)
[ 50] 50 L/min (PF3A801H)
[ 100] 100 L/min (PF3A802H)
[0.00] 0 s
[0.00] 0 s
[FLoW] Flow rate
[ HYS] Hysteresis mode
[ 2_P] Normal output
[ 500] 500 L/min (PF3A801H)
[1000] 1000 L/min (PF3A802H)
[ 50] 50 L/min (PF3A801H)
[ 100] 100 L/min (PF3A802H)
[0.00] 0 second
[0.00] 0 second
[ 1.0] 1 second
[0.10] 0.1 second
[ 0.0] 0%
[ oFF] Reverse display OFF
[ 1.0] 1%F.S. cut
[ 0.0] 0%
[diSP] Display
[diSP] Display
[diSP] Display
[ oFF] Not stored
[ on] Display ON
[ oFF] Not used
[ oFF] Not used
[- - -. -] No input signal
[
n] Normal output
[ oFF] Not used
-32-
Applicable
Page
Page
33
Page
37
Page
44
Page
45
Page
46
Page
47
Page
48
Page
52
Page
53
Page
54
Page
55
Page57
Page
59
Page
60
Page
68
No.PF※※-OMY0005

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pf3a802h-l

Table of Contents