Citizen SA-SD Operation Manual page 90

Controller for contact-type displacement sensors
Table of Contents

Advertisement

Type
NPN
Model
PNP
SA-SD1AP-P
Response time
Output 1 indicator lamp
Output 2 indicator lamp
Output 3 indicator lamp
Input indicator lamp
Preset indicator lamp
Display
Display resolution
Display range
Protection standard
Pollution level
Operating ambient
temperature
Operating ambient
humidity
Operating altitude
Insulation resistance
20 MΩ or higher with 250-VDC megger tester (across whole charged section and case)
Withstanding voltage
Resistance to vibration
10 to 150 Hz, 0.75 mm double amplitude for two hours in each of X, Y, and Z directions
Resistance to impact
Materials
Includes 0.2-mm
2-core brown and blue
lead wires, and 2-m
Cables
length 0.15-mm
7-core composite
Mass (main body only)
Approx. 140 g
Standards applied
Note 1: If not otherwise specified, measurement conditions are as follows: power supply voltage:
+24 VDC; operating ambient temperature: +20°C.
Note 2: Current consumption does not include analog current output.
Note 3: Stated linearity is for digital measurement value, with F.S. = 16 mA.
Note 4: When slave units are connected to the master unit, the maximum inflow/outflow current of the
control output and the operating ambient temperature depends on the number of slave units
connected, as shown in the following table.
Number of slave units connected
1 to 7 units
8 to 15 units
Note 5: Do not use controllers under a pressure higher than atmospheric pressure at altitude 0 m.
Master unit
High performance type
SA-SD1AP
SA-SD1AC
SA-SD1AC-P
Switchable between 3 ms, 5 ms, 10 ms, 100 ms, 500 ms, and 1,000 ms
Orange LED (Lit when Output 1 is ON)
Orange LED (Lit when Output 2 is ON)
Orange LED (Lit when Output 3 is ON)
White LED (Lit when Input is ON)
Green LED (Lit during preset)
Circle meter: Orange/green LCD; Copy check mark: Orange LCD
Digital display MAIN: White LCD; Digital display SUB: Green LCD
Guide mark arrow keys: White LCD; Guide mark ENT: White LCD
Status mark TRIG: White LCD; Status mark HOLD: White LCD
Status mark CALC: White LCD
−199.9999 to 199.9999 mm
−10 to 50°C (provided there is no condensation or freezing) (Note 4);
During storage: −20 to +60°C
35 to 85% RH; During storage: 35 to 85% RH
2,000 m or less (Note 5)
1,000 VAC for one minute (across whole charged section and case)
2
98 m/s
(approx. 10 G), five times in each of X, Y, and Z directions
Case: polycarbonate; Cover: polycarbonate; Switches: polyacetal
2
Includes 2-m length
2
0.15-mm
7-core
2
composite cable
cable
Approx. 140 g
Maximum inflow/outflow
current of control output
20 mA
10 mA
9- 2
Slave unit
Standard type
SA-SD1C
SA-SD1C-P
0.1 µm
IP40 (IEC)
2
Includes 2-m length
2
0.15-mm
6-core
composite cable
Approx. 130 g
EMC Directive
Operating ambient temperature
−10 to +45°C
Wire saving type
SA-SDNC
Approx. 60 g

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents