Peak hold (Trigger mode: One shot)
While the external trigger input is OFF, the peak value is constantly updated, but this is an internal process
and it does not appear on the display or as the judgment output.
When the external trigger input is turned ON (at a rising edge), the internally updated peak value becomes the
new hold value.
HIGH setting value
LOW setting value
TRIG
TRIG display
HOLD display
Judgment output
Note
An indefinite state is held during the following intervals:
From the time immediately after the power is turned ON until the external trigger is turned ON.
From the time the reset input is turned ON until the external trigger is turned ON.
In this type of sample hold, the judgment output is the same as the judgment value.
(However, please note that there are some measurement modes for which this is not the case.)
Related information
The relationship between Peak, Bottom, and Peak-to-peak (Peak-to-peak/2) is shown below.
HIGH setting
HIGH設定値
value
LOW setting
LOW設定値
value
TRIG
Operation procedure
Operation is the same as for the sample hold type in the preceding section.
Select the appropriate measurement mode (MEAS) from P-H, B-H, P-P, and P-P/2.
(Light OFF)
TRIG
(消灯)
HOLD
(消灯)
Go
Indeterminate
不定
6- 21
TRIG
Hi
Peak
ピーク
Peak-to-peak
ピークtoピーク
Bottom
ボトム

Hide quick links: