6-2-1-5 Self Sample Hold (Delay Timer)
Parameter name
Measurement mode (MEAS)
Self trigger level
(SLF.LV)
Self trigger edge direction
(SLF.EDG)
Self trigger delay
(SLF.DLY)
Delay timer (DLY.TIM)
After exceeding or falling below the specified self trigger level (depending on the specified self trigger edge
direction), the judgment value is held automatically on expiry of a period specified by the delay timer.
Fulfillment of the above condition activates self triggering, which updates the judgment value. Until that time,
the output continues to be held.
HIGH setting value
LOW setting value
Self trigger level
TRIG
TRIG display
HOLD display
Judgment output
Note
An indefinite state is held on occurrence of any of the following:
The power is turned ON
The reset input is ON
A sensor head disconnection error or upthrust error (alarm) is canceled
If the input value falls below the self trigger level before the time set by the delay timer has elapsed,
the controller enters an alarm state. (In the case of the self trigger edge direction being set to UP)
Selects a hold mode.
S-H (Sample hold)
P-H / B-H / P-P / P-P/2
NG-H (NG hold)
SLF.S-H (Self sample hold)
SLF.P-H (Self peak hold)
SLF.B-H (Self bottom hold)
Sets the reference level for the hold function using the self
(internal) trigger.
−199.9999 to 199.9999
Sets the edge direction for measurement of the hold value
using the self trigger level.
UP (Rise) / DOWN (Fall)
Sets the self trigger delay type and its reference value
when the self sample hold function is used.
DLY.WD (Static width) /
DLY.TIM (Delay timer)
0 to 199.9999 (mm)
(No effect)
(Light
OFF)
6- 26
Setting value
[Default: S-H]
[Default: 0.500]
[Default: UP]
[Default: DLY.WD]
[Default: 1000]
Remarks