6-2-6 Analog Output Settings

6-2-6-1 Analog Scaling
Parameter name
Analog scaling (ANALOG)
If set to DEFALT, the lower limit is fixed at 0.0000, and the output is 4 mA.
The upper limit is fixed at a specific value that depends on sensor head type, and the output is 20 mA.
When the judgment value is equal to or less than the lower limit, the output is 4 mA, and when it is equal to or
greater than the upper limit, the output is 20 mA.
Operation procedure
Long press
for 2 s
Note
The analog output is specified as follows:
Resolution: 0.3 µA
Output during error: 0 mA
Linearity: ±0.25% F.S.
Maximum load impedance: 250 Ω MAX
Setting value
For analog output, sets the upper and lower limits corresponding
to judgment value (JUDGE.V) converted to current (4 to 20 mA).
DEFALT (Default) / FREE (Free)
Select
Commit
6- 36
Remarks
[Default: DEFALT]
Cancel