Citizen SA-SD Operation Manual page 32

Controller for contact-type displacement sensors
Table of Contents

Advertisement

Detailed settings (ADVANC)
HOLD settings (HOLD)
Measurement mode (MEAS)
Trigger mode (TRG)
Self trigger level
(SLF.LV)
Self trigger edge direction
(SLF.EDG)
Self trigger delay
(SLF.DLY)
Static width (DLY.WD)
Delay timer (DLY.TIM)
All input (ALL IN)
External input (EXT.IN)
External output (EXT.OUT)
Display digits (DIGIT)
Analog scaling (ANALOG)
Scaling upper limit (ANA.HI)
Scaling lower limit (ANA.LO)
Eco mode (ECO)
Selects a hold mode.
S-H (Sample hold) / P-H (Peak hold) /
B-H (Bottom hold) / P-P (Peak-to-peak hold) /
P-P/2 (Peak-to-peak hold/2) / NG-H (NG hold) /
SLF.S-H (Self sample hold) /
SLF.P-H (Self peak hold) /
SLF.B-H (Self bottom hold)
Selects the external trigger input behavior.
1SHOT (One shot) / HOLD (Hold)
Sets the reference level for the hold function using the self
(internal) trigger.
−199.9999 to 199.9999
Sets the edge direction for measurement of the hold value
using the self trigger level.
UP (Rise) / DOWN (Fall)
Sets the self trigger delay type and its reference value when
the self sample hold function is used.
DLY.WD (Static width)
/ DLY.TIM (Delay timer)
Sets a stable fluctuation width until start of hold.
0 to 199.9999 (mm)
Sets a delay time until start of hold.
0 to 199.9999 (mm)
When a trigger is input to a master unit, the signal can be
input to all connected slave units simultaneously.
ONE (Single) / ALL (All)
For input 1/input 2/input 3 of external inputs, selects one of
four input signal types.
P/R/T (Preset/Reset/Trigger) / BANK/P (Bank A/B/Preset) /
BANK/R (Bank A/B/Reset) / BANK/T (Bank A/B/Trigger)
For output 1/output 2/output 3 of external outputs, selects
one of four output signal types.
3VAL (HI, GO, LO) / 2VAL (HIorLO, INRANGE, ALARM) /
LOGIC (LOGIC, ALARM) / LOGIC2
Changes the number of digits shown after the decimal point
on the digital display.
0.1 / 0.01 / 0.001 / 0.0001
For analog output, sets the upper and lower limits
corresponding to judgment value (JUDGE.V) converted to
current (4 to 20 mA).
DEFALT (Default) / FREE (Free)
Sets the scaling upper limit when analog scaling is set to
FREE.
−199.9999 to 199.9999 (mm)
Sets the scaling lower limit when analog scaling is set to
FREE.
−199.9999 to 199.9999 (mm)
Saves energy by turning off the backlight of the controller
display when the screen is not being used.
ON / OFF
6- 2
[Default: S-H]
[Default: HOLD]
[Default: 0.500]
[Default: UP]
[Default: DLY.WD]
[Default: 0.0100]
[Default: 1000]
[Default: ONE]
[Default: P/R/T]
[Default: 3VAL]
[Default: 0.0001]
[Default: DEFALT]
[Default: 10.0000]
[Default: 0.0000]
[Default: OFF]