6-2-1-1 Sample Hold Settings
Parameter name
Measurement mode (MEAS)
Trigger mode (TRG)
An external trigger input holds a normal measurement value as the judgment value.
The hold behavior can be set using the trigger mode.
Sample hold (Trigger mode: Hold)
■
While the external trigger input is ON, the sample is held; while it is OFF, the sample hold is released.
HIGH setting value
HIGH設定値
LOW setting value
LOW設定値
TRIG
TRIG
TRIG display
TRIG表示
HOLD display
HOLD表示
Judgment output
判定出力
Note
■
When the reset input is turned ON with the external trigger input ON, an indefinite state will be
held.
In this type of sample hold, the judgment output is the same as the judgment value.
(However, please note that there are some measurement modes for which this is not the case.)
Related information
■
For details of trigger input as external input, refer to "6-2-3 External Input."
Selects a hold mode.
S-H (Sample hold)
P-H / B-H / P-P / P-P/2
NG-H
SLF.S-H / SLF.P-H / SLF.B-H
Selects the external trigger input behavior.
HOLD (Hold) / 1SHOT(One shot)
TRIG
(Light OFF)
(消灯)
HOLD
(Light OFF)
(消灯)
Lo
Go
Hi
6- 18
Setting value
[Default: HOLD]
TRIG
HOLD
Lo
Go
Remarks
[Default: S-H]