Citizen SA-SD Operation Manual page 67

Controller for contact-type displacement sensors
Table of Contents

Advertisement

6-2-6-2 Scaling Upper Limit/Scaling Lower Limit
Parameter name
Scaling upper limit (ANA.HI)
Scaling lower limit (ANA.LO)
Operation procedure
Setting the scaling upper limit
Long press
for 2 s
Setting the scaling lower limit
Long press
for 2 s
Setting value
This can be set only when analog scaling is set to FREE.
It sets the judgment value that outputs a current of 20 mA
−199.9999 to 199.9999 (mm)
This can be set only when analog scaling is set to FREE.
It sets the judgment value that outputs a current of 4 mA.
−199.9999 to 199.9999 (mm)
Select
Commit
Select
Commit
6- 37
Remarks
[Default: 10.0000]
[Default: 0.0000]
Cancel
Shift between
Change numerical
digits
values
Cancel
Shift between
Change numerical
digits
values