6-1-5 Tolerance <±> (TOL <±>)
Parameter name
Tolerance <±> (TOL <±>)
Teaching method
This sets the HIGH and LOW
setting values automatically
using one reference work.
One-point teaching
This is used to judge work with a
±tolerance.
Operation procedure
Long press
2秒長押し
for 2 s
HI.SET
LO.SET
Related information
Setting Tolerance <±> only has an effect when the one-point teaching is selected.
For details of how to set the teaching method, refer to the preceding section.
When executing the one-point teaching, this parameter is set in
order to provide a tolerance from which the HIGH and LOW
setting values are derived, with the master work measurement
taken as the center value.
0.0000 to 199.9999 (mm)
Setting
ADVANC
CALC
COPY
BANK
TEACH
TEACH
Select
選択
Commit
確定
6- 9
Setting value
[Default: 0.1000]
+Tolerance = Tolerance
HIGH setting value
+Tolerance
Setting value
−Tolerance
LOW setting value
CALIB
RESET
MAINTE
/
PR.VAL
PR.OBJ
PR.SAVE
DIRECT
Cancel
キャンセル
Shift between
Change numerical
digits
values
桁移動 数値変更
Remarks