Advertisement

6-1-4 Teaching (TEACH)

Parameter name
Teaching mode (TEACH)
Teaching method
This sets the HIGH and LOW
setting values automatically
using one reference work.
One-point teaching
This is used to judge work with
a ±tolerance.
∗ Initial status
This sets the HIGH and LOW
setting values automatically
using two reference works.
This is used to judge work
Two-point teaching
according to whether it falls
between an upper and lower
limit.
This sets the HIGH and LOW
setting values automatically using a
satisfactory work, HIGH defective
work, and LOW defective work.
It assumes the upper limit to be the
median of the satisfactory and
Three-point teaching
HIGH defective work values, and
the lower limit to be the median of
the satisfactory and LOW defective
work values. This type of teaching
is used to judge work according to
whether it falls between these
upper and lower limits.
Operation procedure
Long press
2秒長押し
for 2 s
HI.SET
LO.SET
Related information
For details of how to set tolerance for the one-point teaching, refer to the following page.
For details of the teaching methods, refer to "5-3 Teaching Mode."
Sets the method for automatic teaching of tolerance.
TCH.1 (One-point) / TCH.2 (Two-point) / TCH.3 (Three-point)
ADVANC
CALC
COPY
HYSTER
Select
選択
Commit
確定
6- 8
Setting value
[Default: TCH.1]
Setting
+Tolerance = −Tolerance
+Tolerance
Setting value
−Tolerance
HIGH setting value
= (Setting value 1 + Setting value 2) / 2
LOW setting value
= (Setting value 2 + Setting value 3) / 2
Setting value 1
Setting value 2
Setting value 3
BANK
CALIB
RESET
MAINTE
/
TOL <±>
PR.VAL
PR.OBJ
PR.SAVE
Cancel
キャンセル
Remarks
HIGH setting value
LOW setting value
HIGH setting value
LOW setting value
HIGH setting value
LOW setting value
DIRECT
LEVER
SPEED
OUTPUT