External Input/Output; Interface; Input/Output Circuit - Citizen SA-SD Operation Manual

Controller for contact-type displacement sensors
Table of Contents

Advertisement

7. External Input/Output

7-1 Interface

7-1-1 Input/Output Circuit

SA-SD1AP, SA-SD1AP-P
Color
Brown
Black
White
Black/gray
Pink
External input 1
Violet
External input 2
Pink/violet
External input 3
Blue
Gray
Analog output
Shield
Analog ground
Note 1: Use shielded wires for analog outputs.
SA-SD1AC, SA-SD1AC-P
Color
Black
White
Black/gray
Pink
External input 1
Violet
External input 2
Pink/violet
External input 3
Gray
Analog output
Shield
Analog ground
Note 1: Use shielded wires for analog outputs.
SA-SD1C, SA-SD1C-P
Color
Black
White
Black/gray
Pink
External input 1
Violet
External input 2
Pink/violet
External input 3
Note 1: Power is supplied through master unit connectors.
Signal
I/O
+V
Output 1
OUT
Output 2
OUT
Output 3
OUT
IN
IN
IN
0 V
OUT
Signal
I/O
Output 1
OUT
Output 2
OUT
Output 3
OUT
IN
IN
IN
OUT
Signal
I/O
Output 1
OUT
Output 2
OUT
Output 3
OUT
IN
IN
IN
7- 1
Remarks
24 VDC
Refer to "6-2-4 External Output."
Refer to "6-2-3 External Input."
Ground for power supply
Current output (4 to 20 mA)
Remarks
Refer to "6-2-4 External Output."
Refer to "6-2-3 External Input."
Current output (4 to 20 mA)
Remarks
Refer to "6-2-4 External Output."
Refer to "6-2-3 External Input."

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents