Chapter 5
Configuration Procedures for the Cisco 67x CPE Devices
Step 2
Step 3
Step 4
Note
Configure PPP over ATM with NAT
Step 1
Step 2
Step 3
Step 4
78-11190-01
Manually enter this information in the TCP/IP properties on the PC, then click
OK to save the TCP/IP configuration.
Restart the PC.
After the PC has restarted, try to ping the Ethernet address of the CPE. If the ping
fails, check the hardware connections and the configuration on both the PC and
the CPE.
If the CPE is configured for NAT, the default LAN IP network is
10.0.0.0, and the default subnet mask is 255.255.255.0. You can
assign an IP address to your PC starting at 10.0.0.2 with a subnet
mask of 255.255.255.0. The default gateway, which is the IP address
of the Ethernet on the CPE, is 10.0.0.1.
To configure the CPE for PPP over ATM with NAT enabled, log in to the
management port of the CPE in privileged mode.
Erase any saved configuration. Enter:
set nvram erase
Enter:
write
Enter:
set ppp wan0-0 login login
where login is the username provided by your network administrator.
Enter:
set ppp wan0-0 password password
where password is the password provided by your network administrator.
Configure PPP over ATM with NAT
Cisco 600 Series Installation and Operation Guide
5-45