End Of Travel Limit Phasing; Figure 2-6: End Of Travel Limit Input Diagnostic Display - Aerotech Automation1 SI4 Series Hardware Manual

Stepper controller
Table of Contents

Advertisement

2.2.2.1. End of Travel Limit Phasing

2.2.2.1. End of Travel Limit Phasing
If the EOT limits are reversed, you will be able to move further into a limit but be unable to move out. To
correct this, swap the connections to the CW and CCW inputs at the Feedback connector or swap the
CW and CCW limit functionality in the software using the EndOfTravelLimitSetup parameter. View the
logic level of the EOT limit inputs in the Diagnostics display (shown in
34
Figure 2-6:
End of Travel Limit Input Diagnostic Display
SI4 Hardware Manual
Figure
2-6).
www.aerotech.com