If this area has to be accessed for preparatory or maintenance work, ensure that
-
-
In addition to these Operating Instructions, the safety rules of the robot manufacturer
must be followed.
Covers and side parts must only be opened/removed during maintenance and repair
work.
During operation:
-
-
Personal Protec-
Magnetic fields generated by high amperage may eject ferromagnetic parts, such as
tion and Protec-
spatter accumulations, from the cleaning aperture. To prevent injury, always wear pro-
tion of Others
tective goggles with side protection and never look into the cleaning aperture when the
device is switched on.
Keep persons, especially children, away during the operation of the devices and during
the welding process. If persons are in the vicinity, however:
-
-
-
EMC Device Clas-
Devices in emission class A:
sifications
-
-
Devices in emission class B:
-
EMC device classification as per the rating plate or technical data.
Safety Measures
A toppling device can be deadly! Set up the device securely on an even, solid surface
at the Setup Loc-
-
ation and During
Special regulations apply in areas at risk of fire or explosion
Transport
-
Use instructions and checks within the company to ensure that the vicinity of the work-
place is always clean and organized.
Only set up and operate the device in accordance with the degree of protection shown
on the rating plate.
Install the device with an all-round clearance of at least 0.5 m (19.69 in.) to walls, neigh-
boring devices, or other objects.
8
the entire system is shut down for the duration of access to this area
and remains shut down to prevent unintended operation, e.g., as a result of a control
error
Ensure that all covers are closed and all side parts have been mounted properly.
Keep all covers and side parts closed.
Instruct them about all dangers (blinding hazard due to arcs, injury hazard due to fly-
ing sparks, welding fumes hazardous to health, noise exposure, possible hazard due
to grid current or welding current, possible hazard due to electromagnetic fields,
possible hazard due to the magnetic field of the cleaning aperture, moving mechan-
ical parts, compressed air/parting agent mixture discharged from the cleaning aper-
ture, flying chips or similar, etc.),
Provide suitable protective equipment or
Construct suitable protective walls and curtains.
Are only designed for use in industrial settings
Can cause line-bound and radiated interference in other areas
Satisfy the emissions criteria for residential and industrial areas. This is also true for
residential areas in which the energy is supplied from the public low-voltage grid.
A tilt angle of no more than 10° is permitted.
Follow the appropriate national and international regulations.
Need help?
Do you have a question about the Robacta TSS /i and is the answer not in the manual?
Questions and answers