4. Installing the level sensor

Tools Required

-
-
Installing the
Level Sensor
54
Torx screwdriver TX25
5 mm wrench
1
2
2
2
3
5
4
7
6
7
Pull the spring pins of the collecting
1
tray to the left and right and swing col-
lecting tray out
Remove three TX25 screws on the left
2
Remove three TX25 screws on the
3
right
3
3
Remove frame
4
4
Open flap for parting agent container
5
Apply level sensor to the threaded pin
6
on the flap
Use two 5 mm hexagonal nuts to
7
secure the level sensor