Grid Connection

Devices with a high output can influence the energy quality of the grid due to
their current consumption.
This may affect a number of device types in terms of:
-
-
-
*)
See technical data
In this case, the operator or the person using the device should check whether or
not the device is allowed to be connected, where appropriate through discussion
with the power supply company.
IMPORTANT! Ensure secure grounding of the grid connection!
Residual current
Local regulations and national guidelines may mean that a residual current cir-
circuit breaker
cuit breaker is required when connecting a device to the public grid.
The residual current circuit breaker recommended for the device by the manu-
facturer can be found in the technical data.
Personal Protec-
You are exposed to numerous hazards while handling the device, for example:
tion and Protec-
-
tion of Others
-
-
-
-
-
Wear suitable protective clothing when dealing with the device. The protective
clothing must have the following properties:
-
-
-
-
-
Protective clothing involves the following:
-
-
-
-
-
Keep persons, especially children, away during the operation of the devices and
during the welding process. If persons are in the vicinity, however:
-
-
-
8
connection restrictions
criteria regarding maximum permissible grid impedance
criteria regarding the minimum required short-circuit power
both at the interface with the public grid
Flying sparks and pieces of hot metal
Arc radiation that poses a risk of injury to the eyes and skin
Hazardous electromagnetic fields that pose a risk of death for individuals
with pacemakers
Electrical risks from grid current and welding current
Increased noise exposure
Harmful welding fumes and gases
Flame resistant
Insulating and dry
Covering the entire body and in good condition with no damage
Safety helmet
Cuffless pants
Protecting the face and eyes from UV radiation, heat and flying sparks with a
face guard featuring a regulation-compliant filter
Wearing regulation-compliant protective goggles with side protection behind
the face guard
Wearing rigid, wet-insulating footwear
Protecting hands with appropriate gloves (featuring electrical insulation and
thermal protection)
Wearing ear protection to reduce noise exposure and protect against injury
Instruct them about all hazards (blinding hazard due to arcs, risk of injury
from flying sparks, welding fumes hazardous to health, noise exposure, pos-
sible hazard due to grid current or welding current, etc.)
Provide suitable protective equipment or
Construct suitable protective walls and curtains.
*)
*)