ALL:
All operating modes are reset.
Left display Right display
TIG - 2nd level Setup menu
For setting the following parameters:
-
-
-
-
-
-
-
-
-
-
-
2nd level Setup menu
For viewing "system active time", "system on time", "fuse" and "software version"
parameters
For setting the "time shut down" parameter
Parameters in
The following parameters are available through the second level of the TIG Setup
the TIG - 2nd
menu:
level Setup
menu
Welding circuit resistance
For displaying the total resistance of the torch hosepack, welding torch, work-
piece, and return lead cable
IMPORTANT! The ground earth connection and contact of the tungsten elec-
trode must be made on a cleaned workpiece surface.
1
2
3
4
If an error occurs while determining the welding circuit resistance, "r" is dis-
played on the left display and "Err" is displayed on the right display.
74
r (welding circuit resistance)
Slope Time 1 (only in 4-step mode)
Slope Time 2 (only in 4-step mode)
Trigger
HF ignition
Pulse TAC display
Ignition Time-Out
Arc break monitoring
TIG Comfort Stop - Comfort Stop sensitivity
Break voltage
Main current changeover
Establishing a ground earth connection
Select "r" and press the dial
The last measured value is displayed on the right display.
Place the tungsten electrode flush against the workpiece surface
Press the torch trigger or gas-test button
The value for "r" is determined, the right display shows "run".
The current value for "r" is then displayed in MOhm on the right display.