System Configuration
Note
Setting the Security Level
Note
Polycom, Inc.
On the Ringing Mode section, from the Mode drop-down list select one of
2
the following options: Ringing cadence follows (I)PBX or Local
generated ringing cadence.
Select the Minimum Ring Time (ms) value: minimum length of each
3
alerting period, as seen by KIRK Wireless Server 8000 (default is 500).
If a new ring start is seen within MinRingTime then it will be ignored (Valid
values are between 40 and 120 units of 10 milliseconds.)
Click Save to write the changes to the system.
4
You can specify the voice encryption level and the authentication level for the
system.
On the System menu, click Configuration. The System Configuration
1
page is displayed.
Figure 4-8
Security Level settings
Under DECT Security, select the Encription Level and the Authentication
2
Level.
Select or deselect Check Authentication on incoming voice calls and
3
Check Authentication on outgoing voice calls check-boxes.
Enter the System access code in the corresponding field and then click
4
Save to write the configuration to the system.
Repeaters (WRFPs) do NOT support voice encryption. If voice encryption is
enabled all the RFPs (base stations) need to be of the RFP5 generation.
General System Settings