Download Print this page

Nikon JAA79551 Repair Manual page 79

Af-s vr zoom nikkor ed 70-300 / f4.5-5.6g

Advertisement

  《Reference》
 ・The laser spot beam is irradiated about 18mm in diameter at 5 m ahead.
5 mm
45mm
40mm
 ・How to obtain the minimum value of the vibration width
  ① Measure the vibration width while changing the adjustment value that is set every 0.02Step as shown below.
  ② The peak section of the minimum vibration width can be obtained by the actual measured value.
  ③ Take the center of the peak section as the adjustment value.
  Notes:When measuring the vibration width, read it in unit of 0.5mm.
 ① To adjust the vibration width at the center of the
 laser spot beam, measure the whole vibration width
 ② Subtract the radius of the laser spot (oblique lined
  vibration width.
 Example)
13mm
8mm
 When the whole vibration width is [About 40mm],
 the center vibration width becomes be
 45 - (2.5 + 2.5) = 40mm.
 Standard after the gyro gain adjustment
40 × 1/5 = 8mm (Center vibration width)
Whole vibration width becomes be
8+ (2.5+2.5) = 13mm.
Gyro Gain
Adjustment
Value
  ・         ・
  ・        ・
0. 90    15. 0mm
0. 92    14. 5mm
0. 94    14. 0mm
0. 96    13. 5mm
0. 98    13. 0mm
1. 00    13. 0mm
1. 02    13. 0mm
1. 04    13. 5mm
1. 06    14. 0mm
1. 08    14. 5mm
1. 10    15. 0mm
  ・        ・
  ・    
- A 52・AF-S VR 70-300/4.5-5.6G -
first.
part) from the top and bottom of the measured
Vibration width
Actual measured
value
 
INC
JAA79551-R.3690.A

Advertisement

loading