Zoom ring unit
① Mount the zoom ring unit on the SWM, and fix with the
four screws (#140).
(For this mounting, refer to the positional relationship
between "Index" and "MR head" in "Fig. 1".)
Caution:
Whenever the zoom ring unit is mounted,
do NOT touch the MR head.
If pressure is put on
the MR head from
outside, the position is
misaligned, resulting in
a change of accuracy.
② After attaching a distance-scale sticker on the SWM, attach two pieces of the tape [TA-0012 (3mm×12mm].
  (The distance-scale sticker has the adhesive double-coated tape attached.)
SWM
TA-0012
Distance-scale tape
Align the position of the protrusion with
the cutout of the distance-scale sticker.
Grease: OS-30MF
Apply to the overall surface
of the flock tape.
Index
MR head
Fig.1
- A 5・AF-S VR 70-300/4.5-5.6G -
Fit the projected part of the distance-scale
sticker in the groove of the SWM.