(3) Writing aberration compensation data
① Prepare a camera (D100). Set the "Exposure mode" to "A", the aperture to full and "Focus mode" to "S".
On the shooting menu, set the "Image quality mode" to "FINE", "Image size" to"L", "WB" to "Preset", and
"ISO" to "200".
② Set up the camera (D100), in which the lens to be inspected is fit, on the tripod. Set the focal length to
300 mm, and the distance between the test chart and camera (CCD face) to 9 m 00 �2 cm.
(Test chart)
③ As shown below, set the center of the focus area on the chart within viewfinder.
④ Connect the PC and camera via USB cable. (Camera setting: Mass storage)
⑤ Start the adjustment software (LWM.exe).
9 m 00 ± 2 cm
(Within viewfinder)
- A 71・AF-S VR 70-300/4.5-5.6G -
INC
JAA79551-R.3690.A
, "WB" to "Preset", and
"WB" to "Preset", and
�2 cm.
2 cm.
(CCD-face position)
Target chart
Resolution chart