Light-shielding sheet
・Attach the light-shielding sheets (#141 and #142) on the lead groove ring.
  � � [#141] and [#142] have the adhesive double-coated tape attached.)
3rd lens-group holding tube unit
★ J11338
#141
#142
① Mount the rotary tube on the lens stand ( ★ J11338) [With the rotary
tube being mounted, this lens stand is used until the assembly of
the front fixed-tube (i.e. ④ of Page A9) ]
② Get the marked "A" part of the 2nd lens-G holding tube to come
to the cutout-side of the lead groove ring. Then lift and slide only
the rotary tube, and mount the 2nd lens-G holding tube by fitting
its three projections in the three straight grooves of the lead groove
ring.
③ While lift and slide only the rotary tube, mount the 3rd lens-G
holding unit by fitting its three projections in the three straight
grooves of the lead groove ring.
3rd lens-G holding tube unit
2nd lens-G holding
tube
Rotary tube
Cutout
- A 7・AF-S VR 70-300/4.5-5.6G -
INC
JAA79551-R.3690.A
Lead groove ring
"A" part
★ : New tool
★ J11338