Focus ring unit
・ Mount the focus ring unit on the SWM unit, by aligning the three protrusions of the focus ring unit with the
three grooves of the SWM unit.
Protrusion
Mounting of SWM-assembled unit
① Turn the focus tube unit, which is assembled in the front fixed-tube, all the way to the end in the direction of
the arrow. (Then, the key groove is positioned as shown in "Fig.1".) (Fig.1)
② Rotate the focus ring unit of the SWM-assembled unit until "∞" infinity-end position.
③ After assembling the SWM-assembled unit into the front fixed-tube, rotate the focus ring unit and check that
the distance scale can move therewith. (Fig.2)
④ Tighten three screws (#121).
Caution:
When the SWM-assembled unit is mounted, do
NOT let the MR head touch the front fixed tube.
Key groove
Groove
Index
Fig.
Focus tube unit
- A 6・AF-S VR 70-300/4.5-5.6G -
Grease: OS-30MF
Apply to the overall surface of the flock tape.
Focus ring unit
Grease: MZ-800S
Apply to the sliding surface with the lens body.
Groove
SWM unit
Groove
"Fig.1".) (Fig.1)
Fig.1".) (Fig.1)
".) (Fig.1)
.) (Fig.1)
#121×3
Adhesive: Screw lock
INC
JAA79551-R.3690.A
SWM-assembled unit
Focus ring unit
Front fixed-tube
Fig. 2