Mount fixed-tube
① Attach the focusing-index window and the name plate on the mount fixed tube.
�Focusing-index window and the name plate have the adhesive double-coated tape attached.)
② Pass the change-SW unit of the lens body through the hole of the mount fixed tube, and assemble them.
Align the indexes
- A ・AF-S VR 70-300/4.5-5.6G -
Mount fixed-tube
Focusing-index window
Name plate
�ole of mount fixed-tube
Grease: MZ-800S
Apply to the overall sliding surface
with the focus ring unit.
Change-SW unit
Lens body
INC