Typical Configurations - Rockwell Automation Allen-Bradley 1715-AENTR User Manual

Redundant i/o system
Table of Contents

Advertisement

Typical Configurations

Table 39 - 1715 Devices in a SIL 2 System
Firmware
Revision
Cat. No.
2.001 or
1715-AENTR
later
2.001 or
1715-IB16D
(1)
later
2.001 or
1715-OB8DE
(1)
later
2.001 or
1715-IF16
(1)
later
2.001 or
1715-OF8I
(1)
later
1715-A2A
N/A
1715-A3IO
N/A
1715-N2T
N/A
1715-N2S
N/A
1715-C2
N/A
(1) For revision 3.001 and later, the 1715 I/O module firmware displayed is the revision that is installed on the I/O module.
For earlier revisions 1715 I/O module firmware is displayed as the same level of the firmware of the 1715-AENTR module
regardless of the actual firmware level in the 1715 I/O module.
See the latest certifications for software and firmware at
rok.auto/certifications. See the TÜV website at
http://www.tuvasi.com
All I/O modules include line monitoring capability. We recommend that you
use line monitoring for safety-related I/O. Safety-related I/O refers to an
annunciator being available to an input or output that is attached to a field
device. For energize-to-action (normally de-energized) I/O, you must enable
line monitoring.
The 1715 system supports single module configurations, where it is acceptable
to either stop the system or allow the signals corresponding to that module to
change to their default fail-safe state. It also supports fault-tolerant I/O
configurations where the system is required to continue operating in the event
of a fault.
Fault tolerant systems have redundant modules that let the system continue
operation in the presence of a fault. The system fails safe if another fault
occurs.
All configurations can be used for safety-related applications. Choose the
appropriate configurations that are based on the fault tolerance requirements
of your application.
Rockwell Automation Publication 1715-UM001J-EN-P - December 2020
Chapter 7
1715 Redundant I/O System in SIL 2 Safety Applications
Description
Ethernet adapter redundant module N/A
16-channel digital input module
8-channel digital output module
16-channel analog input module
8-channel analog output module
Adapter base unit
I/O module base unit
Tall slot filler cover
Short slot filler cover
Expansion cable - 2 m
for SIL 2 certification listings.
Termination Assembly
Cat. No.
Description
1715-TASIB16D
Digital input simplex
1715-TADIB16D
Digital input duplex
1715-TAS0B8DE
Digital output simplex
1715-TADOB8DE
Digital output duplex
1715-TASIF16
Analog input simplex
1715-TADIF16
Analog input duplex
1715-TASOF8
Analog output simplex
1715-TADOF8
Analog output duplex
N/A
N/A
N/A
N/A
N/A