SMA Sunny Island 5048 Installation Instructions Manual page 154

Hide thumbs Also See for Sunny Island 5048:
Table of Contents

Advertisement

Troubleshooting/Problem Solving
7.
Press <ENTER> again and start the emergency charge
mode (ECM).
You can interrupt the emergency charge mode, for example, to refill diesel.
8.
Press <ENTER> to stop the Sunny Island 5048. The
following message appears.
9.
Hold <ENTER> pressed down and the remaining time is
shown using bars on the display.
10. The emergency charge mode was interrupted and the
display shows the following message:
To prematurely end the emergency charge mode, you must restart the Sunny
Island 5048 using the "#410.01 InvRs" parameter.
In the emergency charge mode, the process values are shown on the display.
Parameters cannot be changed during the charging process.
If the device is restarted, the settings that were saved before the ECM are loaded.
See the instructions for restarting the device and wait five minutes (see also section
9.5 "Reactivating the Device Following Automatic Shutdown" (Page 63).)
Page 154
SI5048-11:EE4206
SMA
Technologie AG
To start ECM
press <ENTER>
Hold key to stop
################
Hold key to stop
###########
To start ECM
press <ENTER>
Technical Description

Advertisement

Table of Contents
loading

Table of Contents