18.2 Adjustable System Parameters

Parameters marked with (Stby) are to be changed only when the Sunny Island
5048 is in standby mode. Once the "ENTER" key is pressed, operating data
values can immediately change to their new settings. Incorrect values in these
parameters can probably not be corrected quickly enough to avoid potential
damage to your system.
All menu items that can only be changed after entering the installer password are
shaded in gray in the following tables.
All parameters can be set using a connected PC/laptop with the Sunny Data
Control software, a Sunny WebBox or a Sunny Boy Control (see section 6.5
"Interface for External Communication" (Page 51)).
#210 Inverter Settings
Menu
Para-
Parameter name
no.
meter
no.
#210
01
InvVtgNom
#210
02
InvChrgCurMax
#210
03
InvFrqNom
#220 Battery Settings
Menu
Para-
Parameter name
no.
meter
no.
#221 Battery Property
#221
01
BatTyp
#221
02
BatCpyNom
#221
03
BatVtgNom
#221
04
BatTmpMax
Technical Description
Range/
Value
Short
descr.
V
230
A
22
Hz
50
Range/
Default
Short
value
descr.
VRLA
VRLA
FLA
NiCd
Ah
100
V
48
degC
40
Description
nominal inverter voltage
230 = 230V_50HZ
220 = 220V_60HZ
depending on the setting in QCG
maximum AC charging current
nominal inverter frequency
50 = 230V_50HZ
60 = 220V_60HZ
depending on the setting in QCG
Description
Battery type:
= valve regulated lead acid
= flooded lead acid
= nickel cadmium
can only be changed in QCG
nominal battery capacity (C10)
can only be changed in QCG
nominal battery voltage
48 = VRLA
48 = FLA
45.6 = NiCd
can only be changed in QCG
maximum battery temperature
SI5048-11:EE4206
Parameter Lists
Page 129