10 Pre-installation
10.3

Installation examples

A
C
A
1
Aluminium profile system
2
Plasterboard wall
3
Reinforced concrete wall and brick wall
4
Plasterboard wall
10.4

Fastening requirements

Base material
Steel
Aluminium
Reinforced concrete
Wood
Brick wall
* Besam minimum recommended requirements. Building Codes may give different specifications.
** Thinner wall profiles must be reinforced with rivnuts.
30
1
3
Minimum requirements of wall profile*
5 mm**
6 mm**
min. 50 mm from the underside
50 mm
Expansion-shell bolt, min. M6x85, UPAT PSEA B10/25, min. 50
mm from the underside
Issue 2014-10-28
2
Non combustible
material in fire ap-
B
plication
A
4
B
A
Steel reinforcement or rivnut
B
Wood reinforcement
C
Expansion-shell bolt (for brick wall min.
M6x85, UPAT PSEA B10/25)
Non combustible
material in fire
application
1007913-EI-9.0