Assa Abloy SW60 Installation And Service Manual
Assa Abloy SW60 Installation And Service Manual

Assa Abloy SW60 Installation And Service Manual

Swing door operator
Hide thumbs Also See for SW60:
Table of Contents

Advertisement

Quick Links

Installation and Service Manual
Entrance Systems
Swing Door Operator
Original instructions
ASSA ABLOY SW60
Original instructions

Advertisement

Table of Contents
loading

Summary of Contents for Assa Abloy SW60

  • Page 1 Installation and Service Manual Entrance Systems Swing Door Operator Original instructions ASSA ABLOY SW60 Original instructions...
  • Page 2 © ASSA ABLOY Entrance Systems, 2023 ® The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by ASSA ABLOY is under license. Technical data subject to change without notice.
  • Page 3: Table Of Contents

    Safety precautions ..................................Electronic equipment reception interference ........................Environmental requirements ..............................Technical specifications ................................ Permitted door weight and door width ..........................How the ASSA ABLOY SW60 works ..........................Door mode functionality ................................6.1.1 HOLD/AUTO/OFF switch ............................. Modes and functions on app ..............................
  • Page 4 11.2 Control unit (CU) ................................... 11.3 Remote control device 433Mhz (option) ..........................Start-up ...................................... 12.1 Spring pre-tension (not include concealed installation) ....................12.2 App ........................................12.2.1 Install the app ................................12.2.2 Log in to the app with owner ........................... 12.2.3 Learn ....................................
  • Page 5: Revision

    1 Revision Revision Following pages have been revised: Page Revision 3.0 → 4.0 Updated. 1022077-en-4.0 Issue 2023-01-17...
  • Page 6: Presentation Of Notes And Warning Signs

    2 Presentation of notes and warning signs Presentation of notes and warning signs Various symbols and texts are used in this manual for easier understanding and identification. Note! When you see Note! it contains useful advice and information to ensure correct and com- pliant usage of the system.
  • Page 7: Warning: Important Safety Instructions. Follow All Instructions Since Incorrect Installation Can Lead To Severe Injury

    3 WARNING: Important safety instructions. Follow all instructions since incorrect installation can lead to severe injury. WARNING: Important safety instructions. Follow all instructions since incorrect installation can lead to severe injury. Failure to observe the information in this manual may result in personal injury or damage to equipment.
  • Page 8 3 WARNING: Important safety instructions. Follow all instructions since incorrect installation can lead to severe injury. The operator can be used by persons with impaired physical, sensory or mental capacity if they have been instructed by a person in charge of their safety concerning use of the appliance in a safe way and understand the hazards involved.
  • Page 9: Important Information

    4 Important information Important information Intended use The ASSA ABLOY SW60 is an automatic swing door operator developed to facilitate entrances to buildings and within buildings through swing doors. For escape in emergency situations the doorset is opened manually. Make sure that the connection to the source of supply by a flexible cord shall not be allowed to become entrapped in moving parts of the operator or door system.
  • Page 10: Technical Specifications

    5 Technical specifications Technical specifications Ensure that the door operator with technical specification below is suitable for the installation. Manufacturer: ASSA ABLOY Entrance Systems AB Address: Lodjursgatan 10, SE-261 44 Landskrona, Sweden Type: ASSA ABLOY SW60 Mains supply: 100-240 V AC +10/-15%, 50/60 Hz, mains fuse max 10A (building install-...
  • Page 11 5 Technical specifications This product is to be installed internally. Concealed without spring Concealed with spring 1022077-en-4.0 Issue 2023-01-17...
  • Page 12: Permitted Door Weight And Door Width

    5 Technical specifications Permitted door weight and door width PUSH arm PULL, Sliding PUSH arm and Concealed with spring Door width (m) Concealed without spring Door width (m) Issue 2023-01-17 1022077-en-4.0...
  • Page 13: How The Assa Abloy Sw60 Works

    6 How the ASSA ABLOY SW60 works How the ASSA ABLOY SW60 works The swing door operator ASSA ABLOY SW60 uses a motor which is connected to the output shaft. The arm system that is connected to the output shaft opens the door.
  • Page 14: Opening

    6 How the ASSA ABLOY SW60 works 6.2.6 Opening When an activation signal is received by the control unit, the door is opened at the installer-adjusted opening speed. Before the door is fully open at back check, it slows automatically to low speed.
  • Page 15: Function Of Locks

    6 How the ASSA ABLOY SW60 works 6.2.16 Function of locks The control unit has an available output of DC for external locks The lock output is short circuit proof and can supply a lock with 12 V DC, max. 1200 mA or 24 V DC, max.
  • Page 16: Part Identification

    7 Part identification Part identification Issue 2023-01-17 1022077-en-4.0...
  • Page 17 7 Part identification Item No. Art. No. Description 330000884 Back plate with power cable 331020445PD Spindle cover kit (Grey) 331019785 Bracket power plug 331020810BK Endplate with control switch (Black) 331019591BK Endplate (Black) 330000883 Control unit (CU) 330000882 Transmission unit (with spring) 330000890NA Cover (Silver) 331703711...
  • Page 18: Arm Systems

    8 Arm systems Arm systems PUSH arm Reveal Reveal Art. No.: 1020224 0 - 68mm Art. No.: 1019456 56 - 130mm PULL arm Art. No.: 1021736 Reveal Issue 2023-01-17 1022077-en-4.0...
  • Page 19: Sliding Push Arm

    8 Arm systems Sliding push arm Art. No.: 1021736 Reveal Concealed with spring Art. No.: 1023677 Concealed without spring Art. No.: 1021754 1022077-en-4.0 Issue 2023-01-17...
  • Page 20: Pre-Installation

    9 Pre-installation Pre-installation General tips/Safety concerns In all instances, where work is being done, the area is to be secured from ped- estrian traffic to prevent injury. In all instances, where work is being done, the main power is to be removed to prevent injury.
  • Page 21: Operator/Door Handing

    9 Pre-installation Operator/Door handing Operator/Door handing (DIN Right or DIN Left) is determined by which side the hinges are mounted seen from the swing side. DIN Left DIN Right Installation examples Non combustible material in fire application Non combustible material in fire application Aluminum profile system Steel reinforcement or rivet nut...
  • Page 22: Fastening Requirements (But Not Included)

    Brick wall Expansion-shell bolt, min. M6x85, UPAT PSEA B10/25, min. 50 mm from the underside * ASSA ABLOY Entrance Systems minimum recommended requirements. Building Codes may give different specifications. ** Thinner wall profiles (3-5 mm) must be reinforced with rivet nuts.
  • Page 23: Mechanical Installation

    10 Mechanical installation Mechanical installation Note! Consider all power wire entry locations and signaling wires before preparing back plate. Please do not touch the PCB during installation to prevent static breakdown. 10.1 PUSH arm system 1. PUSH arm Installation movie Shaft extension Reveal DIN Left...
  • Page 24 10 Mechanical installation 4. Mount the arm The flat face of the extend shaft should be aligned to groove flat face on the arm. Encoder Motor Metal Wood (2x) Note! Do not remove the jumper. Issue 2023-01-17 1022077-en-4.0...
  • Page 25 10 Mechanical installation DIN Right 2. Mount the backplate Reinforced concrete Wood Metal (Min. 4x) Note! Screw head must be flush with backplate surface. Note! The mark on the back plate must be in line with CL pivot. 3. Mount the operator M5x55 (4x) Note! The direction of the arrow on the operator should be same as opening...
  • Page 26 10 Mechanical installation 4. Mount the arm The flat face of the extend shaft should be aligned to groove flat face on the arm. Note! Do not remove the jumper. Wood Metal (2x) Motor Encoder Issue 2023-01-17 1022077-en-4.0...
  • Page 27: Pull Arm System

    10 Mechanical installation 10.2 PULL arm system 1. PULL arm Installation movie Shaft extension Reveal Note! Arm sliding track must be mounted at the top of the door and the back plate at the Z-measurement from top of the door. DIN Right 2.
  • Page 28 10 Mechanical installation 4. Mount the Arm Metal Wood (2x) When reveal A ≠ 0, push the arm with angle 2 - 3° to get pre-tension, but don’t exceed. Please check spring pre-tension. Encoder Motor When reveal = 0 Note! Do not remove the jumper. Issue 2023-01-17 1022077-en-4.0...
  • Page 29 10 Mechanical installation DIN Left 2. Mount the backplate Note! Screw head must be flush with backplate surface. Reinforced concrete Wood Metal (Min. 4x) Note! The mark on the back plate must be in line with CL pivot. 3. Mount the operator M5x55 (4x) Note! The direction of the arrow on the operator should be same as...
  • Page 30 10 Mechanical installation 4. Mount the Arm (2x) Wood Metal When reveal A≠ 0, push the arm with angle 2 - 3° to get pre-tension, but don’t exceed. Please check spring pre-tension. When reveal = 0 Motor Encoder Note! Do not remove the jumper.
  • Page 31: Sliding Push Arm System

    10 Mechanical installation 10.3 Sliding PUSH arm system 1. Sliding PUSH arm Installation movie Shaft extension Reveal DIN Left 2. Mount the backplate Note! Screw head must be flush with backplate surface. Reinforced concrete Wood Metal (Min. 4x) Note! The mark on the back plate must be in line with CL pivot.
  • Page 32 10 Mechanical installation 4. Mount the Arm Wood Metal (2x) Pull the arm with angle 2 - 3° to get Encoder pre-tension, but don’t exceed. Please check spring pre-tension. Motor Note! Do not remove the jumper. Issue 2023-01-17 1022077-en-4.0...
  • Page 33 10 Mechanical installation DIN Right 2. Mount the backplate Reinforced concrete Wood Metal (Min. 4x) Note! Screw head must be flush with backplate surface. Note! The mark on the back plate must be in line with CL pivot. 3. Mount the operator M5x55 (4x) Note! The direction of the arrow on the operator should be same as the...
  • Page 34 10 Mechanical installation 4. Mount the Arm (2x) Wood Metal Pull the arm with angle 2 - 3° to get pre- tension, but don’t exceed. Please check spring pre-tension. Motor Encoder Note! Do not remove the jumper. Issue 2023-01-17 1022077-en-4.0...
  • Page 35: Concealed With Spring

    10 Mechanical installation 10.4 Concealed with spring 1. Concealed with spring Installation movie DIN Right 2. Adjust the operator Note! Only adjust the operator for DIN Right. Don't adjust the operator for D- IN Left. 3. Mount the operator Wood Metal 1022077-en-4.0 Issue 2023-01-17...
  • Page 36 10 Mechanical installation 4. Mount the arm ST5.5x32 (2x) Push the arm with angle 2 - 3° to get pre-tension, but don’t exceed. Encoder Motor Note! Do not remove the jumper. Issue 2023-01-17 1022077-en-4.0...
  • Page 37 10 Mechanical installation 1. Concealed with spring 2. Mount the operator DIN Left Wood Metal 1022077-en-4.0 Issue 2023-01-17...
  • Page 38 10 Mechanical installation 3. Mount the arm ST5.5x32 (2x) Push the arm with angle 2 - 3° to get pre-ten- sion, but don’t exceed. Motor Note! Do not remove the jumper. Encoder Issue 2023-01-17 1022077-en-4.0...
  • Page 39: Concealed Without Spring

    10 Mechanical installation 10.5 Concealed without spring 1. Concealed without spring Installation movie DIN Right 2. Adjust the operator Note! Only adjust the operator for DIN Right. Don't adjust the operator for D- IN Left. M5x50 (4x) 3. Mount the operator Metal Wood (4x)
  • Page 40 10 Mechanical installation 4. Mount the arm ST5.5x32 (2x) Push the arm with angle 2 - 3° to get pre-tension, but don’t exceed. Encoder Motor Note! Do not remove the jumper. Issue 2023-01-17 1022077-en-4.0...
  • Page 41 10 Mechanical installation 1. Concealed without spring 2. Mount the operator DIN Left (4x) Wood Metal 1022077-en-4.0 Issue 2023-01-17...
  • Page 42 10 Mechanical installation 3. Mount the arm ST5.5x32 (2x) Push the arm with angle 2 - 3° to get pre-ten- sion, but don’t exceed. Motor Note! Do not remove the jumper. Encoder Issue 2023-01-17 1022077-en-4.0...
  • Page 43: Electrical Connection

    11 Electrical connection Electrical connection The installation shall be made according to local codes. During any work with the electrical connections the mains must be disconnected. 11.1 Mains connection Push arm / Pull arm / Sliding push arm Power adaptor Power adaptor Concealed with spring Power adaptor...
  • Page 44: Control Unit (Cu)

    11 Electrical connection 11.2 Control unit (CU) Power connector Power PCB (Lock-) (Lock+) (NA) (NA) (NA) (Key impulse) (Outer impulse) (Inner impulse) HOLD AUTO Basic I/O PCB Learn button Motor PCB Motor Encoder Issue 2023-01-17 1022077-en-4.0...
  • Page 45: Remote Control Device 433Mhz (Option)

    11 Electrical connection 11.3 Remote control device 433Mhz (option) Remote control (2x) Receiver (1x) Brown Yellow White Green 1022077-en-4.0 Issue 2023-01-17...
  • Page 46: Start-Up

    (When press the Learn button on CU for concealed installation, must push the door leaf to the opening position more than 45°.) 12.2.1 Install the app Download the ASSA ABLOY Swing Door Manager app from the Google Play or App Store. Issue 2023-01-17 1022077-en-4.0...
  • Page 47: Log In To The App With Owner

    12 Start-up 12.2.2 Log in to the app with owner 1022077-en-4.0 Issue 2023-01-17...
  • Page 48: Learn

    12 Start-up 12.2.3 Learn Must learn before start up. Note! Before pressing Learn button, make sure that "Bluetooth" and "Location" on your mobile phone is opened. * Press Learn button on CU for ** Scan QR code on the label that more than 4 seconds.
  • Page 49: Test

    12 Start-up Back-check Latch-check The back-check will be automatically adjusted to 10° and 1 second before open position. The latch-check will be automatically adjusted to 10° and 1.5 seconds before closed position. 12.2.4 Test 12.2.5 Settings 1022077-en-4.0 Issue 2023-01-17...
  • Page 50: Add User By Owner

    12 Start-up 12.2.6 Add user by owner Note! Owner can add up to 7 users. 12.2.7 Remove user by owner Issue 2023-01-17 1022077-en-4.0...
  • Page 51: Log In To The App With User

    12 Start-up 12.2.8 Log in to the app with user At the same time, owner click “Add user” and show the QR code. User scan the QR code from owner. 12.2.9 The differences between owner and user Functions Owner User Factory reset Show users Add user...
  • Page 52: Additional Door Information

    12 Start-up 12.2.10 Additional door information 12.2.11 Configuration parameters Parameter name Default settings Value Hold open time 2s - 6h Opening time 4.5s 3s - 8s Closing time 4.5s 4.5s - 9s Arm system Push / Pull / Sliding push / Concealed in- Push / Pull / Sliding push / Concealed in- stallation stallation...
  • Page 53: Cover

    13 Cover Cover Secure cover with screw. Apply the ASSA ABLOY logotype to the cover, see below. Push arm / Pull arm / Sliding push arm Remove the plastic film 1022077-en-4.0 Issue 2023-01-17...
  • Page 54 13 Cover Concealed with spring (option) M3x5 (4x) Remove the plastic film Concealed without spring installation Remove the plastic film Issue 2023-01-17 1022077-en-4.0...
  • Page 55: Signage

    14 Signage Signage SIGNAGE according to ANSI/BHMA A156.19 Surface Applied shown Action If problem occurs Check that all required signage is applied and intact. Mandatory indicates that the signage is required by European directives and equivalent national legislation outside the European Union. Dual Side "AUTOMATIC DOOR / CAUTION"...
  • Page 56: Troubleshooting

    15 Troubleshooting Troubleshooting Fault Possible reasons why Remedies/Explanations The door does not open Control switch is set to OFF Change the setting of the control switch The motor does not start Mains power is missing Check the mains power and fuse in the building LED light blinks Door is in error Remove power, wait 10 seconds.
  • Page 57: Service/Maintenance

    Service/Maintenance Regular inspections shall be made according to national regulations and product documentation by an ASSA ABLOY Entrance Systems-trained and qualified technician. The number of service occa- sions should be in accordance with national requirements and product documentation. This is especially important when the installation concerns a fire-approved door or a door with an emer- gency opening function.
  • Page 58 Building on the long-term success of the Besam, Crawford, Albany and Megadoor brands, we offer our solutions under the ASSA ABLOY brand. Our products and services are dedicated to satisfying end-user needs for safe, secure, convenient and sustainable operations.

Table of Contents