15 Classification
15
Classification
15.1
Entering the program mode (classification)
If the operator is equipped with batteries, they must be disconnected before the following procedure
is preformed.
• Disconnect the mains plug
• Press the LEARN BUTTON while connecting the mains plug
• Watch the ERROR LED
3 s
• Release the LEARN BUTTON after the second 5 s has passed
15.2
Identify the current classification
The ERROR LED flashes an amount of short flashes that correspond to the classification number.
After a short pause the LED will repeated the classification number and so on.
15.3
Changing the classification
If you push the LEARN BUTTON once, the classification number will increase. When you have reached
the highest classification number it will start at number one again.
• Push the button until you get the requested classification
• Disconnect the mains plug
Next time you connect the mains the operator will use the new classification.
15.4
Classification table
Classification
Standard
Opening speed
Closing speed
The fastest setting of Opening Speed and Closing Speed are automatically limited to the value in
the table, and can only be reduced.
If classification 2, Low energy, is used the operator will automatically follow the speed limitation
in DIN 18650-2.
The learn procedure must be carried out after a change of the classification setting.
76
1 s
5 s
1 s
1
Full power
Default
2,5 - 12 s
4 - 12 s
Issue 2014-10-28
5 s
2
Low energy
DIN 18650-2
Automatic limitation, 3-12 s
Automatic limitation, 4-12 s
1007913-EI-9.0