11 Mechanical installation
e Release the brake, by pushing in the forks so that the brake is opening, before mounting the
coordinator base (14) with the two screws (7) on the master drive unit. Remove the screw (8)
and mount the acceptor (10) on the adjuster (9). Mount the screw (8) through the acceptor
(10).
Adjust the adjuster (9) by turning until the master door stops at 15-18° from fully closed. Close
the door by pressing the linkage arm (13).
10
8
f
Mount the link rod with its adaptor (12) into the linkage arm (13).
g Mount on the other side of the link rod (11) to the slave motor unit with the signal (15). Fasten
the stop screw (16).
52
7
14
11
12
15
Issue 2014-10-28
13
11
16
9
1007913-EI-9.0