Finalize Installation

Attach Covers to finalize installation
1. Align cut-outs in each cover to
corresponding pinion shafts.
2. Slide covers onto units using end caps and
union spacers as guides.
NOTE: Verify all wiring and sheet metal
guards are inside cover.
3. Snap covers securely to backplates. Pull on
covers to verify they are secure.
NOTE: If cover will not securely snap onto
backplate, verify backplate is not warped or
twisted. Additional support or shimming may
be required. See Sections A & B under Prepare
Frame and Door.
You've now installed the D6001DE-L Low Energy Operator.
Continue with separate Programming Manual 80-9360-1049-020

General Electrical Information

y Power inputs at power input connection and
power output contacts must be made with
copper wire only.
y Maximum wire size:
12 AWG at power input connection
14 AWG at all other terminals.
y Power input at terminals LINE and NEUTRAL
must be 120VAC at 60 Hz (+10%, -15%).
Auxiliary Dry Contacts
Powered Output
Contacts
14
D6001DE-L Series Double Egress Power Operator Unit
WARNING: Make sure no wiring is loose or can be
caught by cover when it is snapped into place.
for operator setup and adjustments.
Copyright © 2023, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or in part
without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
Approved 2023-11-10
Pinion Shaft Cut-out
Figure 35
y Maximum current draw from auxiliary
devices is 1.3 amps.
y All wiring and connections use standard
wiring practice conforming with local wiring
codes.
y Labeled fire or smoke barrier door
assemblies require 120VAC 60Hz power
input be supplied through normally closed
alarm contacts of the alarm system / alarm
panel.
Power On/Off
Switch
Power Input
and Basic Aux
Connection
Pinion Shaft Cut-out
Powered Output
Contacts
Auxiliary Dry Contacts
80-9360-1048-020 Rev 1 01/23