14 Changing group of parameters

14
Changing group of parameters
a Disconnect batteries if any.
b Disconnect the electrical power contact.
c Press the LEARN BUTTON (LRN) and keep it depressed.
d Connect the electrical power contact.
e Watch the ERROR LED.
3 s
f
Release the LEARN BUTTON after the 5 seconds (LED is out).
The ERROR LED flashes a number of short flashes that corresponds to the parameter group
number (see table). After a short pause the LED will repeat the group number, and so on.
g Pushing the LEARN BUTTON once, increases the parameter group number. When the highest
parameter group number is reached it will start with number 1 (default) again.
h Push the button until you get the requested parameter group. Ensure that the requested group
of parameters has been selected by counting the number of flashes.
i
Disconnect the electrical power contact.
j
Next time the electrical power is connected, the operator will use the new group of parameters.
72
1 s
5 s
Issue 2014-10-28
1007913-EI-9.0