Installation

1. Template
Mark and prepare door and jamb (for closer
bracket and arm bracket).
For Vertical Dimensions use "Mounting
Dimensions Chart" (Figure 2)
NOTES:
• Check hand of door. (Figure 1)
• Right Hand Application Shown,
Left Hand Opposite
• Dimensions given in inches (mm).
Do Not Scale Drawing.
• Closer must be installed in a true
horizontal plane to ensure proper closer
performance.
• Door opening (up to 180°) is dependent
upon door, frame, wall and hinge/pivot
conditions permitting.
• Maximum Hinge Side Reveal 1/8" (3mm).
C L
For installation assistance contact Corbin Russwin
1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com
Copyright © 2018 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.
All manuals and user guides at all-guides.com
*10-1/4
(260)
HINGE OR PIVOT
FRAME LINE
A
1
(25.4)
*6-1/4
(159)
* To obtain extra closing force add 3" (77mm) to dimensions marked. This
will limit degree of door opening to 110°.

MOUNTING DIMENSIONS

TOP RAIL
2-1/2" (64mm)
& OVER
1-3/4" (44mm)
-MIN.
Figure 2
B
ARM BRACKET
TOP OF DOOR
4-5/16
(109.5)
3
MINIMUM
CLEARANCE
REQUIRED
DIM. A
DIM. B
OVER DOOR
1"
3/4"
(25.4mm)
(19mm)
5/8"
1-1/8"
(16mm)
(29mm)
2-1/4
(57.2)
CLOSER BRACKET
80-9360-6004-152 04/18
1-11/16"
(43mm)
2-1/16"
(53mm)